![tams elektronik 53-03110 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/tams-elektronik/53-03110/53-03110_manual_816273019.webp)
WIB-31 | WIB-32 | WIB-33
English
Factory settings: The simulation of a defective fluorescent tube is defined for none of the eight
LEDs.
Remark: The setting in CV#125 only takes effect when in CV#115 the fluorescent tube
simulation has been activated (factory settings fluorescent tube simulation deactivated).
Duration of switching on the fluorescent tubes
LED1 | LED2 126 48
0 ... 255 (52) no flickering
0
LED3 | LED4
127 49
0 ... 255 (35) short flickering
1
LED5 | LED6
128 50
0 ... 255 (83) ...
LED7 | LED8
129 51
0 ... 255 (71) long flickering
15
You can choose a value between 0 and 15 for each output. Enter the value directly for the
even LEDs, for the odd LEDs multiply the value by 16.
Example: For LED1 value "2" and for LED2 value "14"
à
Input value: 46 (=2x16 + 14)
Remark: The settings in CV#125 to 129 only take effect when in CV#115 the fluorescent tube
simulation has been activated (in factory settings: fluorescent tube simulation deactivated).
Setting the kicking time for AUX1 and AUX3
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
Kicking time
AUX1 | AUX3
124 46
0 ... 255 (0) = length of time the full
voltage is applied, before
being reduced to the value set
in CV#63 or 64. The max.
time of 10 seconds
corresponds to the value "15".
You can choose a value between 0 and 15 for each output. Enter the value directly for AUX1
and for AUX3 multiply the value by 16.
Example: For AUX1 value "7" and for AUX3 value "3"
à
Input value: 55 (=7 + 3x16)
Choosing presets
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
Choosing
presets
130 52 --
Preset 0
0
Preset 1
1
Preset 2
2
Preset 3
3
Remark: A set value in this variable can be taken over into operation when you proceed as
follows:
1. Performing a reset (i.e. entering an optional value in CV#8).
2. Supplying the vehicle shortly with power (i.e. setting the vehicle shortly onto the powered layout).
3. Entering in CV#130 the desired value, afterwards altering the address and making further
modification, if necessary.
9. Presets
Factory settings
(default values)
Preset 0
Applications /
Examples
Control car
Switching all functions
individually
Switching the
LEDs
F1: each 2nd LED
F2: remaining LEDs
all LEDs individually
with F1 to F8
Dim switch
to be switched with F4
to be switched with F10
Fluorescent tube
simulation
off
off
Random light
for AUX3
for AUX3
Orientation light
to be switched with F3
to be switched with F9
AUX1
F0, on at backwards
motion
F0, on at backwards
motion
AUX2
F0, on at forwards
motion
F0, on at forwards
motion
AUX3
Random light,
not to be switched
Random light,
not to be switched