![tams elektronik 53-03110 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/tams-elektronik/53-03110/53-03110_manual_816273018.webp)
English
WIB-31 | WIB-32 | WIB-33
Settings for the dim switch
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Value in CV#115
0
16
Function keys
for activating
the dim switch
(via LDR)
112 37
1 ... 255 (8) F1
F5
1
F2
F6
2
F3
F7
4
F4
F8
8
F0
F9
16
F10
32
F11
64
F12
128
It is possible to activate the function with several function keys. Remark: If you want to assign
the function keys F5 to F12, you have to set the value "16" CV#115 first.
Factory settings: The dim switch can be activated with F4.
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
Sensivity of
the LDR
(light
depending
resistor)
113 38
1 ... 255
(176)
= Limit value of the
surrounding lighting, when
the LEDs and the outputs are
switched on or off.
A higher value causes the
switching operation to be
activated at a greater light
intensity.
Remark: In default settings the LEDs and the function outputs are switched on when the
surrounding lighting under-runs the limit value. When programmed accordingly (in CV#115)
the performance can be inverted (e.g. to switch the lighting off automatically in a shadow
station).
Settings for the orientation light
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Value in CV#115
0
32
Function keys
for activating
the
orientation
light
118 41
1 ... 255
F1
F5
1
F2
F6
2
F3
F7
4
F4
F8
8
F0
F9
16
F10
32
F11
64
F12
128
It is possible to activate the function with several function keys.
Remark: If you want to assign the function keys F5 to F12 to this function you have to set the
value "32" in CV#115 first.
Factory settings: The orientation light is activated with F3.
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
Brightness of
the orientation
light
119 42
1 ... 255
(16)
The lower the input value the
brighter is the orientation
light.
Settings for the fluorescent tubes
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Settings
Simulation
of a defective
fluorescent
tube
125 47
0 ... 255 (0) LED1
1
LED2
2
LED3
4
LED4
8
LED5
16
LED6
32
LED7
64
LED8
128