English
LD-G-6
Page 36
!
CV-name
CV-
no.
input
value /
(state of
delivery)
remarks
Operation of the
outputs X4 and
X5
56
0 or 1
(1)
This data is set by entering the
sum of the numerical values.
Numerical value
Constant light
0
Lighting according to
direction of travel
1
Operation
Track sections with bad contacts (e.g. some types of points) may give
an unsatisfactory performance. You can improve the locomotive
performance by soldering a capacitor > 100 µF / 35 V to the points X3
and X15 (see fig. 1a and 1b).
FAQ
§
Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: one or more connections are soldered incorrectly.
à
Check the connections.
Possible cause: The connection of the motor is connected to
locomotive ground.
à
Disconnect the connection from locomotive ground.
§
The locomotive lighting does not correspond to its direction of travel.
Possible cause: The forward and reverse light connections have
been exchanged.
à
Check the connections.