Setting up Image
39
2. Specify a suitable value for each item.
Item
Details
Trigger
setting
I/O1
To use as an event trigger, turn ON the check box and
set the make/break status for an operation of input signal
1 to be detected.
Note:
The make/break status detects the following signal
operation.
make
Active LOW
break
Active HIGH
If I/O1 is specified as a trigger, I/O1 cannot be used for
signal output.
I/O1 works as an input port for IR TRG operation if the
IR is set to [Trg] for the TOP image, in which case no
event trigger settings are possible.
•
•
•
I/O
To use as an event trigger, turn ON the check box and
set the make/break status for an operation of input signal
to be detected.
Note:
The make/break status detects the following signal
operation.
make
Active LOW
break
Active HIGH
If I/O is specified as a trigger, I/O cannot be used for
signal output.
•
•
MD
To detect a motion, turn ON the check box.
*MD: Motion Detection
MD
display
Set the ON/OFF status of the frame display for the
subject.
MD
Sensitivity
Set the detection sensitivity (0 to 9).
Dwell time Set the dwell time of motion detection (0 to 9).
Audio IN
To detect a sound, turn ON the check box and set the
microphone sensitivity (0 to 5).
Note: