![Tamron 300QV-P-CM Скачать руководство пользователя страница 33](http://html2.mh-extra.com/html/tamron/300qv-p-cm/300qv-p-cm_instruction-manual_3450881033.webp)
Setting up Image
33
2. Specify a suitable value for each item.
Item
Details
Brightness
Set the brightness (0 to 10).
Contrast
Set the contrast (-5 to +5).
Sharpness
Set the sharpness (-5 to +5) of the image.
Hue
Set the hue (-8 to +8).
Saturation
Set the color saturation (-5 to +5).
EV
Set the exposure value (-5 to +5).
AGC
Set OFF/4dB/30dB as the maximum gain.
Max Exposure
Time
Set the maximum exposure time. Select the maximum exposure
time from 1/60, 1/30, 1/15, /15 to 8/15 (sec).
Note:
The sensitivity increases when a longer maximum exposure time is
set, and this is likely to result in blurred images of moving subjects.
The sensitivity decreases when a shorter maximum exposure time
is set, and this can prevent blurred images of moving subjects.
AWB
Set the AWB/One-Push status of the automatic white balance.
If One-Push is set, the automatic white balance is executed by
clicking [set] and the value is maintained until the next execution.
DNR
Set the OFF/D/D+3D status of noise reduction.
Note:
D: D noise reduction
3D: 3D noise reduction
Flickerless
Set the ON/OFF status of the flicker operation.
Light Frequency
Set the frequency of the circumstance from AUTO/50Hz/60Hz
(Flicker-less mode).
Note:
The AUTO mode enables the automatic detection of the fre-
quency in use.
BLC Area
Splits the entire screen of the original image into 16 areas as
shown below, and sets the ON (red)/OFF (gray) status of the AE
wave detection area.
0
1
3
4
5
6
7
8
9
10
11
1
13
14
15