IMPORTANT! - READ THIS FIRST!
INTRODUCTION
The TAMCO/EBTRON AIR-IQ Airflow Measurement Damper Solution consists of a high-quality TAMCO
damper and factory-installed, precision EBTRON Airflow Measurement Station (transmitter and
flow measurement probes) designed for negative pressure OA (outside air) and unducted return air
applications. Operation of the AIR-IQ in other applications may not be recommended. Please consult your
TAMCO/EBTRON applications specialist for specific applications.
Observe the following precautions during installation to prevent damage and to ensure proper operation of the
AIR-IQ product. Read and understand all of the information contained in this document and in the INSTALLATION
GUIDELINES document, prior to installation of the AIR-IQ. Failure to observe the following precautions can result
in damage to the TAMCO Damper and/or EBTRON equipment that is not covered under warranty.
FOR ADDITIONAL AIR-IQ ASSISTANCE
TAMCO Damper Assembly:
For assistance with specific TAMCO AIR-IQ Damper questions or issues not covered in this document,
contact TAMCO Customer Service at 1-800-561-3449.
EBTRON Airflow Measurement Station:
Refer to the EBTRON Technical Manual TM_GTx116 under separate cover for airflow measurement
station wiring, instrument setup and operation. For additional assistance with EBTRON Airflow
Measurement Station questions or issues not covered in the Technical Manual, contact your local EBTRON
Representative or EBTRON Customer Service at 1-800-232-8766.
CAUTION!
The AIR-IQ Damper is supplied with factory-installed EBTRON airflow measurement probes
transmitter. Exercise caution when unpacking, handling and installing the AIR-IQ to prevent
damage to the EBTRON instruments and the TAMCO damper assembly.
If damper frame damage is noted, contact TAMCO Customer Service for further instructions.
DO NOT HAMMER ANY PART OF THE FRAME, AS DAMAGE TO THE AIRFLOW MEASUREMENT
STATION COMPONENTS THAT MAY RESULT IS NOT COVERED UNDER WARRANTY.
Do not adjust damper linkage mechanism. Tampering with linkage will void damper warranty.
If damper problems remain after completing the PRE-INSTALLATION VERIFICATION (in the
INSTALLATION GUIDELINES document), please call TAMCO Customer Service.
Damper linkage, airflow sensor probes and transmitter must remain accessible after
installation to permit setup and recommended periodic maintenance activities.
Refer to the EBTRON Technical Manual, provided under separate cover for airflow measurement
station wiring, instrument setup and operation.
⚠
⚠
⚠
⚠
⚠