Z-Block Manual version 1.3

Page 14

Tamas Hydronic Systems

End Cap Installation

Autovent Installation

Apply a pea-sized amount of Silicon 

Grease to O-Rings on Autovent. 

A line film of  lubrication

can avoid rolling the O-ring.

1

Push firmly in the vertical direction until 

it reaches the end stop in the Z-Block.

2

3

Push and twist Air Vent clockwise to

seal the connection.

Apply a pea-sized amount of Silicon 

Grease to O-Rings on End Cap. 

A line film of  lubrication

can avoid rolling the O-ring.

1

Push End Cap firmly in the axial direction 

until it reaches the end stop in the Z-Block

2

3

When connected, turn both levers on 

fittings up or down to lock and seal

Assembly

Содержание Z-Block

Страница 1: ...Installation and Assembly Guide Z Block Hydronic Zoning Block www tamashydronic com Tamas Hydronic Systems User Guide ...

Страница 2: ...ries 19 Limited Warranty 20 Table of Contents Note The following parts lists and application drawings are general samplings Each configuration dictates the required components See the Technical Data section of the manual for specific information on each part in your particular variation of the Tamas Zone Block This User Guide is Applicable to Tamas Z Block 025 0050 Z Block Tamas Zone Block Kit Box...

Страница 3: ...y of residential commercial and Industrial applications The Z Block is easy to assemble and install making it suitable for all skill levels This unique design allows the Z Block to be installed in a variety of small spaces for new installations or retro fits Main Features Fully customizable with the option to add pieces to accommodate for specific job requirements Expandable for any residential ap...

Страница 4: ... 58 Three Speed Pump 2 Supply Return Manifold 3 Built in Autovent 4 Pressure Temperature Sensor Optional 5 1 1 4 High Flow Rate Adapter with Sweat Connections 6 Z Block Expansion Connections 7 End Cap with Sensor Port 8 3 4 Sweat Connections 9 Bult in Purge Valve 10 Built in Check Valve Components ...

Страница 5: ...e Return In Zone Supply Out 1 2 3 4 Operation The Z Block distribution manifold works in the following way The heating fluid from the heat emitter enters via connection 1 and returns via connection 2 Delivery to the zone system is via the lower right connection on the Z Block The fluid returning from the zone system connection 3 flows towards the pump connection 4 ...

Страница 6: ...ature 203 F 95 C Pumped Liquid Water or Ethylene Glycol up to 50 Concentrate Electrical Data Main Frequency 60 Hz Rated Voltage 1 x 115 V Current in Speed 1 0 55 A Current in Speed 2 0 66 A Current in Speed 3 0 75 A Dimensions are in Inches Millimeters 130 5 118 115 4 528 35 1 378 40 1 575 56 2 205 198 80 7 827 200 45 7 892 Performance HI MED LOW 20 18 16 14 12 10 8 6 4 2 0 0 2 4 6 GPM Ft 8 10 12 ...

Страница 7: ...ressure drop kPa 100 50 20 10 5 0 0 3 0 0 2 0 0 1 0 5 0 1 5 20 Flow m3 h l min l s Kvs m 3 h 2 1 0 5 0 2 0 1 0 05 5 2 1 0 5 0 2 10 4 5 4 8 1 5 1 6 1 2 1 3 2 2 2 5 3 4 3 6 3 0 3 2 CAPACITY DIAGRAM Only underfloor heating applications Technical Data Temperature Range 45 C 65 C Kvs 3 5 Flow Diagram 3 Way Mixing Valve Optional ...

Страница 8: ...bled and installed in multiple configurations and orientations 1 Boiler Pump As a boiler pump in a multiple zone application You must use optional part 025 0005 180 End Connection for creating primary secondary piping arrangement See page 9 for Z Block inverted pump configuration Zone Pumps Boiler Pump with 180 End Connector ...

Страница 9: ... Block to the manifold in an inverted position In this position the pump head Part 025 0010 will need to be inverted 180 as well To do this remove the 4 pump bolts and turn the pump head to the desired location Replace the screws when finished Do not spin the pump base Remove pump head screws and rotate pump head 180 1 Final Configuration shown on right 2 ...

Страница 10: ...ne application to temper the water temperature You must use optional part 025 0005 180 End Connection for creating primary secondary piping arrangement Injection pump controller not supplied See page 9 for Z Block inverted pump configuration Zone Pumps Zone Pumps Boiler Pump with 180 End Connector Mixing Pump with 180 End Connector ...

Страница 11: ...mas Hydronic Systems Inc The holder document ep all information contained herein confidential and shall protect same in whole or in sclosure and dissemination to all third parties e same for operation and maintenance purposes only Approvals Approved 3 Zone Pump Zoning in a hydronic system for individual or multiple zones The maximum amount of connected Z block modules is 10 in a single supply to t...

Страница 12: ...authorized in writing Tamas Hydronic Systems Inc The holder ment hall keep all information contained herein confidential and shall protect same in or in part from disclosure and dissemination to all third parties hall use same for operation and maintenance purposes only Supply Return 4 Vertical Arrangement The Z Block can be installed in a vertical configuration When installing multiple Z Block mo...

Страница 13: ... in whole or in part from disclosure and dissemination to all third parties 2 Shall use same for operation and maintenance purposes only 5 Vertical Arrangement with a Boiler Pump The Z Block can be installed in a vertical configuration When installing multiple Z Block modules vertically with a boiler pump two optional parts must be used the 180 end connector Part 025 0005 and the sensor vent fitti...

Страница 14: ...firmly in the vertical direction until it reaches the end stop in the Z Block 2 3 Push and twist Air Vent clockwise to seal the connection Apply a pea sized amount of Silicon Grease to O Rings on End Cap A line film of lubrication can avoid rolling the O ring 1 Push End Cap firmly in the axial direction until it reaches the end stop in the Z Block 2 3 When connected turn both levers on fittings up or ...

Страница 15: ...til it reaches the end stop in the Z Block 2 Once the purge valve fitting is fully seated slide the fitting clip into the groove in the port securing the fitting to the block Purge Drain Valve Installation Purge Drain Valve Installation in End Cap Depending on the orientation of the Z Block distribution manifold the purge valve can be installed in one of the end caps To do this drill a 5 mm 02 hol...

Страница 16: ...he O ring with silicone grease if necessary The bayonet connection system does not require the use of tools and as such there is no need to place twisting or crushing force on the modules this could deform or damage these parts thereby affecting their operation Apply a pea sized amount of Silicon Grease to O Rings on Connection Fitting A line film of lubrication can avoid rolling the O ring 1 Push ...

Страница 17: ...tion fitting as shown below 5 To enable the bayonet connection between Z Block modules and the 180 end connection position the Z block with the 180 end connection fitting side by side Push firmly in the axial direction until it reaches the end stop Apply Silicon Grease to O Rings on Connection Fitting a line film of lubrication can assist and avoiding rolling the O ring 1 2 Insert Connection Fittin...

Страница 18: ... 0310 x 2 11 4 Nut 006 0325 x 2 1 Tail Piece 006 0331 x 2 11 4 Nut Seal 006 0332 x 1 Silicon Grease 025 0007 x 1 Sensor Purge Valve Clip 025 0015 x 1 Auto Vent 025 0013 x 1 Purge Valve 025 0014 x 1 Check Valve 025 0018 x 2 5mm Mount Screws 025 0008 x 2 Pump Mount Screws 025 0022 x 1 Pump Base 025 0009 x 1 Pump Head 025 0010 x 1 Pump Base Large O ring 025 0011 x 1 Pump Base Small O Ring 025 0012 x ...

Страница 19: ...tional 22 x 32mm Slip Adapter Fitting 006 0315 Optional 180 End Connector 025 0005 Optional Sensor Vent Fitting 025 0021 Optional Sensor Cable 025 0017 Optional Pressure Temp Sensor 025 0016 Accessories available from Tamas Hydronic Systems INC Phone 1 403 279 0020 Fax 1 403 279 0747 Email info tamashydronic com Optional Accessories ...

Страница 20: ...ic Systems option repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operation of law statutory or otherwise including warranties of merchantability and fitness for a particular purpose application Tamas Hydronic Systems Inc neither assumes nor authorizes any other person to assume for it any other...

Страница 21: ...Tamas Hydronic Systems Inc Page 21 Tamas Hydronic Systems Notes Notes ...

Страница 22: ...Z Block Manual version 1 3 Page 22 Tamas Hydronic Systems Notes Notes ...

Страница 23: ...Tamas Hydronic Systems Inc Page 23 Tamas Hydronic Systems Notes Notes ...

Страница 24: ...om Reliable Hydronic Systems Tamas Hydronic Systems Inc Phone 1 403 279 0020 4516 112 Avenue SE Fax 1 403 279 0747 Calgary Alberta T2C 2K2 info tamashydronic com TamasHydronicSystems TamasHydronic company tamas hydronic systems ...

Отзывы: