TALON TECH CO. LTD.
8-5 Installation Method
8-5-1 Pump Installation Sequence
1. Prepare the space for the pump installation.
2. As per the below picture, tighten the panel base plate with 4 pieces of M4 screw.
8-5-2 Piping Method
1. PR Tube Piping
1) Insert
⅜”
union nuts on tube at PR In/Out / Vent areas.
2) Position between PR bottle and Pump max. closely
3) At the vent area, insert
⅜”
sleeve into tube after enlarging tube with the tube expansion tool
and then tighten nut.
Make 3.4mm hole and Tap M4
M4 Tap 4ea
⅜”
Union Nut
⅜”
Sleeve
PR Drain
PR Out