Fault Messages
145
PRINTER HOT
Yes
This message indicates
internal temperatures
over 60° Celsius (140°
Fahrenheit).
Check printer environment. If hot or
dusty, relocate printer. Contact your
authorized service representative if
this occurs frequently.
1
PRINTER UNDER
REMOTE CONTROL
No
Status message: The
printer is under the
control of PrintNet
Enterprise (PNE) remote
management software.
No action is required.
PROTECTED INSTR*
No
Protected Instruction.
Firmware error on
controller board.
Contact your authorized service
representative.
1
PWR SUPP VOLT *
No
Power Supply Voltage.
The power supply has
failed.
Replace power supply board.
QUEUE OVERRUN
No
In CT twinax emulation,
the print buffer has
overflowed.
Contact your authorized service
representative.
1
RBN AT END POINT
Change Ribbon
Yes
Integrated Print
Management System
software has determined
that the ribbon is out of
ink.
Install a new ribbon.
REGIONx MISMATCH
Use Correct RBN
Yes
The incorrect cartridge
type is being used for the
printer. “X” indicates the
region of the printer.
Install Region X ribbon cartridge in
the printer.
NOTE: Specify the region of the
printer when ordering
ribbons.
REMOVE USED SPX
THEN PRESS ENTER
No
Status message: An SPX
is depleted because it
has successfully
reprogrammed the
security key on the
controller board.
Contact your authorized service
representative.
1
RESTORING BOOT
CODE
No
Normal download
initialization message.
No action is required.
RIB INVLD CMD*
See User Manual
Yes
Ribbon Invalid
Command. Firmware
error on the controller
board.
Cycle power. Run the print job
again. If the message appears,
download the emulation software
again. If the message appears
again, contact your authorized
service representative.
1
Table 8. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation
Solution
Содержание 6605
Страница 1: ...TallyGenicom 6600 Series Printers User s Manual ...
Страница 3: ...User s Manual TallyGenicom 6600 Series Printers ...
Страница 14: ...14 Chapter 1 Contact Information ...
Страница 114: ...114 Chapter 5 RS 232 Serial Interface ...
Страница 150: ...150 Chapter 7 Diagnosing Problems ...
Страница 158: ...158 Appendix B ...
Страница 170: ...170 Appendix C Performance Limitations ...
Страница 176: ...176 Appendix D Stacker Operation ...
Страница 196: ...196 Appendix G Software License Agreement ...
Страница 211: ......
Страница 212: ...255552 001B 255552 001 ...