Tally Dascom DT-210/230 Programming Guide V1.1
- 24 -
<Function 6> GS ( E pL pH fn a (fn = 6)
[Function]
Transmit the customized setting values
[Format]
ASCII
GS ( E pL pH fn a
Hex
1D 28 45 pL pH fn a
Decimal
29 40 69 pL pH fn a
[Range]
(pL + pH × 256) = 2 (pL = 2, pH = 0)
fn = 6
a = 5, 6, 97, 116, 118
[Description]
Transmits the customized value specified by a.
a
Type of customized value
5
Print density
6
Print speed
97
Number of division of thermal head energization
116
Print control (single-color or two-color)
118
Black-color density in two-color printing
<Function 11> GS ( E pL pH fn a d1...dk (fn = 11)
[Function]
Set the configuration item for the serial interface
[Format]
ASCII
GS (
E pL pH fn a d1 ... dk
Hex
1D 28
45 pL pH fn a d1 ... dk
Decimal
29 40
69 pL pH fn a d1 ... dk
[Range]
3≤(pL+ pH×256)≤65535 (0≤pL≤255, 0≤pH≤ 255)
fn = 11
a = 1
48 ≤ d ≤ 57
[Default]
d1...dk = “38400”
(upon shipment)
[Description]
• Sets the configuration item for the serial interface specified by a to the values
specified by d.
a
Configuration item
1
Transmission speed
• Transmission speed settings (a = 1)
d1...dk
Transmission speed
2400
2400 bps
4800
4800 bps
9600
9600 bps
19200
19200 bps
38400
38400 bps
57600
57600 bps
115200
115200 bps
[Note]
• The configuration item set by this function is enabled by executing GS ( E <Function 2>
or restarting the printer. Note that the host computer must be set to enable the
Содержание DT-210