50
1.1.5 power error
Phenomen
on
Possible Cause
Inspection
Recovery
The power
LED is OFF.
AC/DC
power
adapter
is
unplugged.
Check the power adapter.
Re-connect
the
power adapter.
Faulty in AC/DC
power adapter.
Check the power circuit with
multitester.
Replace the power
adapter.
Faulty in power
switch
or
connector.
Check the power switch or
connector with multitester.
Replace the power
switch
or
connector.
Faulty in power
supply circuit in
main board.
Check the power supply
circuit with multitester.
Replace the main
board.
1.1.6 Communications error
Sympto
m
Possible Cause
Inspection
Recovery
The
printer
does not
print.
Unsecured connection
between
communication cable
and printer.
Check
the
communication cable.
Re-connect
the
communication
cable.
The
communication
cable is wrong.
Check
the
communication cable.
Use
the
prescribed
communication
cable.
There is something
wrong
with
communication cable
or connector.
Check the conducting
performance of the
cable and connector
with multitester.
Replace
the
communication
cable
or
connector.
The
communication
interface
board
is
damaged.
Replace
another
communication
interface board for test.
Replace
the
communication
interface board.
The
extending
interface circuit on
main board is faulty.
Replace
another
communication
interface board for test.
Replace
main
board.
Содержание DL-210
Страница 1: ...Maintenance Manual DL 210 Label Barcode Printer Maintenance Manual DL 210 Label Barcode Printer...
Страница 4: ......
Страница 40: ...34...
Страница 61: ...55 2 2 Socket Position on the Main Board...