background image

7.

5. Tone indicator

2) A "beep" tone is issued from the receiver approximately 5 seconds after the cover is put into position.
    This tone indicates the Auto-gain has been set.   Refer to the chart below.

Note 1)
         2)
         3)

A tone is generated regardless of whether "beep" (alignment tone) switch is set to ON or OFF.
The auto-gain setting is locked in for approximately two weeks even if power is disrupted.
If the receiver cover is detached while power is supplied or if power is discontinued for longer than two weeks
(but cover left in place), the auto-gain automatically reset to maximum sensitivity. (Gain is automatically locked
with power re-supplied.)

This feature provides audible testing or signals for the following items.

7. Environmental Module

The environmental signal is initiated if the beam reception level 
is reduced to approx 50% or more. The module "Watches" for a 
gradual degradation of the beam reception which is indicative of 
extremely poor weather conditions. NC or NO signal output is
selectable.
[Contact capacity 30V (AC/DC) 0.5A or less]

Tone

Indicates

Result

Cause

Remedy

Optimal sensitivity has
been set.

One pulse
(Beep)

OK

Continuous
tone (20
seconds)

Optimal sensitivity can
not be set.

NG

1. Beam is interrupted once cover is
    replaced.

2. Beams are mis-aligned and sensitivity
    attenuation LED lights.

1. Remove any blockage items or ensure
    hand is not breaking beam if holding
    cover in temporary position.
2. Check beam power setting at transmitter
    with cover attached and re-adjust beam
    alignment.

Test / Signal

Alignment tone switch

Other condition

Description

Reception strength monitored.  Tone pitch increases as reception
improves.
(Note : No tone is given if sensitivity attenuation LED is lit or

Содержание Quad PB-IN-50HF

Страница 1: ...INDOOR 330 100m PB IN 100HF OUTDOOR 330 100m INDOOR 660 200m PB IN 200HF OUTDOOR 660 200m INDOOR 1320 400m INSTRUCTION MANUAL FEATURE The PB IN HF series beams are equipped with many features which pr...

Страница 2: ...r receiver Avoid light in a direct path of 2 of optical axis Do not install in a site where beam may be interrupted by trees or plants consider seasonal changes Do not install the unit on unsteady sur...

Страница 3: ...0m AWG18 1 00 1017 310m 9187 2800m 920 280m 8203 2500m 820 250m 7218 2200m AWG17 1 10 1246 380m 11156 3400m 1116 340m 9843 3000m 985 300m 8860 2700m AWG16 1 25 1640 500m 14765 4500m 1477 450m 13452 41...

Страница 4: ...tach covers Break knockouts on cover and pole cover to adapt to pole diameter and configuration Grommet The grommet is compatible with a wire of 3mm to 6mm outer dia When a wire of more than 6mm outer...

Страница 5: ...the beam Pre attach cover 5 Attach cover 1 Attach transmitter cover first 2 Confirm that receiver sensitivity attenuation LED stays OFF Place cover in position but do not secure A beep sound will occu...

Страница 6: ...tacked protection This option allows field selection of the appropriate beam intensity relative to the application For distance significantly less than the specified protection distance the beam inten...

Страница 7: ...ental signal is initiated if the beam reception level is reduced to approx 50 or more The module Watches for a gradual degradation of the beam reception which is indicative of extremely poor weather c...

Страница 8: ...itter 4 Readjust to be the same channel does not match with that on receiver Intermittent alarm 1 Bad wiring connection 1 Check again 2 Change of supply voltage 2 Stabilise supply voltage 3 Shading ob...