6. Wiring Distance between sensor and control panel.
Note
• Max. wiring distance
when two or more sets
are connected is the
above value divided by
the number of sets.
• The signal line can be
wired to a distance of
up to approx. 3281’
(1000m) with AGW 22
(Dia. 0.65mm)
telephone wire.
• When using this product in a Mercantile Burglar Alarm, UL681, tamper switch should be connected to a 24-hour supervisory loop.
*Standby battery -
Be sure the control panel is equipped with adequate standby battery and charging circuit.
Use 12V (at least) Nicd or lead acid battery with minimum capacity of 0.5AH.
- Estimated battery life -
• Unit should be
connected to a listed,
class 2 power source
capable of providing
standby power for a
minimum of 4 hours.
PB-IN-50HF
PB-IN-100HF
PB-IN-200HF
Wire Size
Dia.
12V
24V
12V
24V
12V
24V
AWG22 0.65
394' (120m)
3610' (1100m)
361' (110m)
3281' (1000m)
328' (100m)
2953' ( 900m)
AWG20 0.80
690' (210m)
6234' (1900m)
624' (190m)
5578' (1700m)
525' (160m)
4921' (1500m)
AWG18 1.00
1017' (310m)
9187' (2800m)
920' (280m)
8203' (2500m)
820' (250m)
7218' (2200m)
AWG17 1.10
1246' (380m) 11156' (3400m) 1116' (340m)
9843' (3000m)
985' (300m)
8860' (2700m)
AWG16 1.25
1640' (500m) 14765' (4500m) 1477' (450m) 13452' (4100m) 1312' (400m) 11811' (3600m)
AWG15 1.40
2198' (670m) 19686' (6000m) 2000' (610m) 18046' (5500m) 1739' (530m) 15750' (4800m)
AWG14 1.60
2756' (840m) 24936' (7600m) 2494' (760m) 22311' (6800m) 2166' (660m) 19686' (6000m)
PB-IN-50HF
PB-IN-100HF
PB-IN-200HF
No. of
Md AA
Gel Cell
Gel Cell
Md AA
Gel Cell
Gel Cell
Md AA
Gel Cell
Gel Cell
pairs
0.5 AH
1.0AH
5.0AH
0.5 AH
1.0AH
5.0AH
0.5 AH
1.0AH
5.0AH
1
8 hr.
16 hr.
83 hr.
7 hr.
14 hr.
71 hr.
5 hr.
11 hr.
58 hr.
2
-
8 hr.
41 hr.
-
7 hr.
35 hr.
-
5 hr.
29 hr.
4
-
-
20 hr.
-
-
17 hr.
-
-
14 hr.
8
-
-
10 hr.
-
-
8 hr.
-
-
7 hr.
3.
The units can be mounted easily on a
pole or flat surface.
Direction by rotary mirror.
Using the adjustment dial and
adjustment screws, the mirrors can
move horizontally (
±
90 degrees) and
vertically (
±
10 degrees) allowing the
sensor to work in all directions.
•
1)
2)
±
10˚
±
90˚
(Ex.1)
(Ex.2)
(Ex.3)
4
INSTALLATION
Remove cover via
screw at base
of cover.
Loosen screws that fix
the sensor body on the
mounting plate, and
slide the mounting plate
downward to detach it.