background image

OPERATION CHECK

7

Be sure to perform an operation check after the optical axis adjustment.

An alarm is output

Light on

The sensor beams are 
not obstructed

Light entrance due to 
wrap around of the beams

(Due to light entrance caused 
by reflection)

1

2

3

4

Turn off the power to the 
transmitter and check that 
an alarm is output.

Change the height or location of the sensor so 
that the light on the detection line can be 
obstructed completely.

Change over a channel or synchronized timing.

Readjust the optical axis, and move the direction 
of the optical axis away from the reflection surface 
within the allowable range.
(Perform this for both the transmitter and receiver)

Spill-over light entrance

No alarm is output

* It results from the same channel and the same synchronized timing settings.

If no alarm is output

Transmitter

Beep
(high pitch
beep)

Light ON

Shield the light

Shield the light

Light enters

Light enters

Spill-over

No alarm is output

No alarm is output

Wrap around

Walls, etc.

Receiver

Light entrance due to beam wraparound

Spill-over light entrance

Transmitter

Transmitter

Transmitter

Transmitter

Receiver

Receiver

Receiver

Receiver

Set Transmitter LED switch of the transmitter to [OFF] and mount the cover (housing).
When Transmitter LED switch is set to [OFF], the LED light turns off, but the upper 
and lower beams are transmitted.

After the optical adjustment is completed, set Auto Gain Lock switch 
to [ON] under the light beam reception condition, and wait for 
approximately 5 seconds.
During this period, do not shield the optical axis.
A one-time short beep sound [Pi-] shows that the auto gain lock is 
completed correctly.
(After the auto gain lock, the upper and lower LEDs light off.)
Set Reception authorization LED switch of the receiver to [OFF].

Obstruct the sensor beams near the sensor or the center 
of the detection line and check that an alarm can be 
output correctly.

In using the environmental output, 
confirm that the environmental output 
is generated when the optical axes in 
both the upper and lower sections are 
shielded for 20 seconds or more.

If the sound check switch is set to ON, after the auto gain lock 
has been completed normally, the walk test mode is activated 
for 5 minutes. The beep sound is generated in synchronization 
with the alarm output.
The alarm LED lights up according to the alarm output.

After the auto gain lock is completed correctly, the walk test mode is activated 
for 5 minutes regardless of whether the cover is mounted or not. During the 
walk test mode, the beep sound is generated when the alarm LED lights on by 
the alarm output. After approximately 5 minutes has elapsed, the walk test 
mode ends. Even if Auto Gain Lock switch is not set to [ON], set Reception 
authorization LED switch to [OFF] activate the walk test mode for 5 minutes.

How to set Auto Gain Lock by remote control.
The units has terminals for Auto Gain Lock by remote control.
1. Attached the housing cover of receiver side.
   *Set the Auto Gain Lock switch 

“OFF” and set the Auto Gain Lock terminal 

“Open”

2. Change the Auto Gain Lock terminal to “Close”, and wait for 5 sec.
    If a “beep” tone sounds once after 5 sec. the Auto Gain Lock is completed.
   *Don’t block the optical axis while 5 sec for initialize.

The intermittent beep sound like “PiPiPi........” shows 
that the beam reception volume is not enough. In this 
case, the LED on the side of the insufficient reception 
volume blinks. Set Auto Gain Lock switch to [OFF], and 
adjust the optical axis again.
In the multi-level protection, when the light enters from 
other units than the opposing transmitter, turn off the 
power of the other transmitter to stop transmitting the 
light beam, then set Auto Gain Lock switch to [ON].

<<Caution>>

Transmitter

ON

OFF

Transmitter LED switch

Receiver

After 5 seconds

ON

OFF

"Pi-" :   PASS
"PiPiPi......" :  FAIL

Auto-gain Lock 
switch

Bleep 
(High-pitched 
tone)

Содержание PXB-100HF-KH

Страница 1: ...econds the receiver detects this break in the light beams and outputs a signal In order to ensure that the detection line has sufficient margin of sensitivity adjust the direction of the light beams b...

Страница 2: ...NTING HEIGHT 4 3 3 OPTICAL AXIS ADJUSTMENT RANGE 5 3 4 EXAMPLE OF PRACTICAL APPLICATION 5 4 INSTALLATION METHOD 4 1 INSTALLATION INTO HOUSING 6 5 WIRING METHOD 5 1 POSITION AND RATING OF TERMINALS 6 5...

Страница 3: ...e Doing so may cause a fire electrical shock or malfunction of the device If smoke or an abnormal odor or sound is found leaving it unattended may cause a fire or electrical shock Immediately turn off...

Страница 4: ...ric beam sensors causing erroneous detections Therefore be sure to prune such plants regularly 3 Other natural phenomena such as insects or bird droppings may soil the sensors causing miss detection B...

Страница 5: ...w t VUVBM JOUFSGFSFODF PS XSBQBSPVOE PG UIF QIPUPFMFDUSJD CFBNT DBO CF QSFWFOUFE CZ DIBOHJOH UIF DIBOOFMT i 91 5 0 0 6 5 0 4 0 6 5 0 3 26 07 3 6 5 0 w PUF 4FU DPSSFTQPOEJOH USBOTNJUUFST BOE SFDFJWFST...

Страница 6: ...tact c contact Built in contact protection resistance Auto gain lock control 2 1 Size of electrical cable used Part No Supply voltage Up to 16 000ft 4 880m Up to 2 200ft 670m Up to 15 000ft 4 570m AWG...

Страница 7: ...its are connected to the same circuit Basic connections for 2 level protection For environmental output tamper output and alarm memory display in the remote mode When multiple sensor units are connect...

Страница 8: ...within the range of 0 to 90 Next fine adjustments of 0 to 5 can be made using the horizontal angle adjustment screw Fine adjustments Horizontal angle fine adjustment screw Rough adjustments Fine adju...

Страница 9: ...djust so that the sensor of the opposite device is visible at the center of the ring using the horizontal and vertical angle fine adjustment screws Turn on the power to the transmitter and receiver ch...

Страница 10: ...aches the highest pitch Adjust both the transmitter and receiver 3 Fine adjust the lower level optical axis 1 Press the upper lower changeover switch on the transmitter to select Only transmit from lo...

Страница 11: ...Press the upper lower changeover switch on the receiver to select Reception authorization on lower only 3 Turn the adjustment screw to fine adjust until the monitor output voltage reaches the highest...

Страница 12: ...center of the detection line and check that an alarm can be output correctly In using the environmental output confirm that the environmental output is generated when the optical axes in both the upp...

Страница 13: ...n 500ft 150 m Model L H Power PXB 100HF KH PXB 200HF KH E g 200 60 m 295 90 m When PXB 100HF KH is set at a distance of 295ft 90 m set to H When PXB 100HF KH is set at a distance of 200ft 60 m set to...

Страница 14: ...or upper and lower Note Only installed on the receiver The margin of sensitivity on this device is set so that an appropriate sensitivity can be obtained when the optical axis is aligned while the dev...

Страница 15: ...t an intruder could run through at top speed 9 Set the transmission power switch to H remove the receiver cover and set the gain lock again 1 Perform angle adjustment again and set the gain lock 2 Rem...

Страница 16: ...ency selection Tone indicator Environmental module Beam power selection Transmitting power adjutment Alarm memory indication Programmed AGC Auto gain lock function Monitorjack Response time adjustment...

Отзывы: