4-1

INSTALLATION METHOD

4

5-1

INITIAL SETTING

5

In order to avoid cross talk between the same channel, select the different timing setting A or B.

MODULATION FREQUENCY CHANGEOVER

Master : Output the synchronized signal from synchronized output terminal.
Slave    : Transmitter irradiate a beam as setting channel and setting timing according to synchronized input signal from master.

1 2

1 2

1 2

1 2

1 2

4 CH

2 CH

3 CH

1 CH

Factory set : 1CH

* In case of 2 level installation, set the same channel 

and change the synchronized timing.

* In case of more than 3 level installtion, change the 

channel but not neighboring number.

* Set the transmitter and the receiver to the same channel.

Panhead screw

(M3×12mm)

: 4 pcs

(ACCESSORIES)

Housing

(Frame)

* Installed on the transmitter and the receiver

INSTALLATION INTO HOUSING

5-2

* Installed on the transmitter and the receiver

5-3

* Only installed on the transmitter (Receiver to be slave only)

3

3

3

A

B

Factory set : A

* Set the same timing for same transmitter, receiver pair.

* In case add one more set in same synchronized wire group, 
   Please set the different timing.

4

4

4

Master  Slave

Factory set : Master

* Select only one transmitter as Master and others as Slave

* One master for up to 7 slaves (Transmitter : 3, Receiver : 4) in one synchronized 
   wire group.
  

Read the instruction manual for your housing carefully, and install the product into the housing correctly.

Wiring is required based on the sensor installation.
Refer to "6 WIRING METHOD" for wiring and connection.

Refer to "9 EXPLANATION OF FUNCTIONS" for switching channels and transmitting beam power.

MASTER/SLAVE SELECTION

SYNCHRONIZED TIMING

9

Содержание PXB-100ATC-KH

Страница 1: ...nizing the timing of transmitting and receiving beam the stacking system will be more reliable PHOTOELECTRIC BEAM SENSOR Instruction Manual 1 ANTI CRAWL DETECTION 2 AT HF SEPARATE OUTPUT 1 2 3 4 3 SYN...

Страница 2: ...PUT SWITCH RESPONSE TIME SOUND CHECK WIRING METHOD 6 1 6 2 6 3 OPTICAL AXIS ADJUSTMENT 7 1 7 2 OPERATION CHECK EXPLANATION OF FUNCTIONS 9 1 9 2 9 3 9 4 9 5 9 6 9 7 9 8 9 9 TROUBLESHOOTING SPECIFICATIO...

Страница 3: ...UNCTIONS 9 2 UPPER LOWER CHANGEOVER FUNCTION 9 EXPLANATION OF FUNCTIONS 9 2 UPPER LOWER CHANGEOVER FUNCTION Factory set ON Factory set ON Transmission LED Upper lower Light reception authorization LED...

Страница 4: ...ng multi level protection use sensors of the same model for both upper and lower sensors and set the same transmission power H L for all of them 2 Using these sensors together with sensors from a diff...

Страница 5: ...ams is aligned correctly a detection line with sufficient margin of sensitivity is formed 90 Range where the optical axis is shielded 20 20 90 20 20 180 Top View Side view CORRECT CORRECT CORRECT WRON...

Страница 6: ...the infrared beams Only the transmitter can be set as the master A device to transmit or receive the infrared beams based on the input synchronized signal The receiver operates as the slave Timing fo...

Страница 7: ...ter as a master Connect the synchronized units by wire t 1MFBTF OPUF UIBU UIFSF JT BO FMFDUSJD QPMBSJUZ JO B TZODISPOJ FE XJSF 2 Level Stacking Application Transmitter Receiver 1 2 3 4 5 6 7 8 1 2 3 4...

Страница 8: ...t Transmitter 1CH B Slave 2 n d Receiver 1CH B 2 n d Transmitter 3CH A Slave 3 r d Receiver 3CH A 3 r d Not neighboring channel 1CH and 3CH 2CH and 4CH 1CH and 3CH 2CH and 4CH Transmitter Receiver Tra...

Страница 9: ...RIES Housing Frame Installed on the transmitter and the receiver INSTALLATION INTO HOUSING 5 2 Installed on the transmitter and the receiver 5 3 Only installed on the transmitter Receiver to be slave...

Страница 10: ...etails Sound Check Switch ON ON Other settings etc Auto Gain Lock switch OFF without cover The optimum margin of sensitivity has been set The required margin of sensitivity has not been secured Beep s...

Страница 11: ...selected When both of upper and lower beam is shielded simultaneously And gated Response time is 0 05s 2 In case HF output is selected Signal is issued only when both of upper and lower beam is shiel...

Страница 12: ...same group by synchronized wiring Select one transmitter as a master all the others are as slave One master may have maximum 7 slaves Power supply 12 to 30VDC Power supply 12 to 30VDC 1CH A 1CH A 1CH...

Страница 13: ...ply 12 to 30VDC Power supply 12 to 30VDC Alarm N C Env N C Alarm N C Env N C Slave Slave Slave Master Slave Alarm N C Env N C Master PXB 100HF KH PXB 100ATC KH Control panel Control panel Transmitter...

Страница 14: ...ent to 3 Fine adjustments 90 90 5 5 Coarse adjustments Coarse adjustments can be made by moving the swivel base within the range of 0 to 90 Next fine adjustments of 0 to 5 can be made using the horizo...

Страница 15: ...angle adjustment 1 2 Each time the switch is pressed the optical unit that transmits the light switches Transmitter Only transmit from upper Only transmit from lower No transmission Receiver Received...

Страница 16: ...chronazation Connect the synchronizing wire properly Wrong synchronization Flashing Flashing Slave setting sensor only 3 4 Receiver Transmitter Light on Light on Turn on the power to the transmitter a...

Страница 17: ...Adjustment Using the Sound Check 5 Receiver Transmitter To improve accuracy of optical axis Perform the procedure of Optical Axis Adjustment Using the Sound Check Optical Axis Fine Adjustment Using th...

Страница 18: ...e adjustments of the optical axis can be achieved Using the alignment wireless checker enables easy and accurate beam alignment Providing sufficient margin of sensitivity increases resistance to the d...

Страница 19: ...beam reception condition and wait for approximately 5 seconds During this period do not shield the optical axis A one time short beep sound Pi shows that the auto gain lock is completed correctly Afte...

Страница 20: ...set the optimum margin of sensitivity for the receiver in any protection distance This function allows the upper and lower sensors to be switched ON and OFF This function is used to light on off Tran...

Страница 21: ...ensitivity temporarily and to stabilize operation The receiver adjusts this function to start or to stop automatically depending on beam power from transmitter When the Programmable AGC works the beam...

Страница 22: ...4 Readjust the frequency channels so they are the same 5 Match the synchronized timing 1 Connect the power source 2 Check again 3 Remove the reflecting object or change the installation location or o...

Страница 23: ...eless checker ER 02 EXTERNAL DIMENSIONS 12 Unit inch mm Reference installation drawing 4 3 mm 4 0 12 Panhead screws 5 91 150 mm 2 91 74 mm 2 83 72 mm 3 31 84 mm 3 31 84 mm 16 38 416 mm 16 38 416 mm Re...

Страница 24: ...om defects in material and workmanship for 12 months from original date of shipment Our warranty does not cover damage or failure caused by natural disasters abuse misuse abnormal usage faulty install...