WIRING METHOD
6
POSITION AND RATING OF TERMINALS
6-1
WIRING DISTANCE
6-2
11
AWG20 (Dia.0.8mm)
AWG18 (Dia.1.0mm)
AWG17 (Dia.1.1mm)
AWG16 (Dia.1.25mm)
AWG15 (Dia.1.4mm)
AWG14 (Dia.1.6mm)
1,000' ( 300m)
1,550' ( 473m)
1,900' ( 580m)
2,500' ( 750m)
3,100' ( 950m)
4,000' (1,200m)
7,100' (2,160m)
11,000' (3,400m)
13,500' (4,000m)
17,000' (5,200m)
21,500' (6,550m)
28,500' (8,690m)
wire size
voltage
12V DC
24V DC
AWG20 (Dia.0.8mm)
AWG18 (Dia.1.0mm)or more
2,850 ' ( 869m)
3,300 ' (1,000m)
Wire size
Distance
<Transmitter>
<Receiver>
Power input 12 to 30V DC
(non-polarity)
Current consumption : 48mA
Alarm output
(AT output) *1
*2
Alarm output
(HF output)
Synchronized input
(polarity)
*1 In case AT output is selected :
When either upper or lower beam is shielded (Or-gated) - Response time is
set as selected. When both of upper and lower beam is shielded simultaneously (And-gated) -
Response time is 0.05s.
*2 In case HF output is selected : Signal is issued only when both of upper and lower
beam is shielded simultaneously. The response time is 0.05s.
Environmental output
30V(AC/DC) . 0.25A (Resistance load)
Dry contact N.C./N.O.switchable
Built-in contact protection resistance
30V(AC/DC) . 0.25A (Resistance load)
Dry contact N.C./N.O.switchable
Built-in contact protection resistance
30V(AC/DC) .0.25A (Resistance load)
Dry contact N.C./N.O.switchable
Built-in contact protection resistance
* Maximum 3,300ft(1,000m) and not more.
Power input 12 to 30V DC
(non-polarity)
Current consumption : 27mA
Synchronized output
(polarity)
Synchronized input
(polarity)
(AWG description)
[ft]
[ft]
(AWG description)
Distance between sensor and power supply
Synchronized wiring distance
* In case two or more sensors connected, divide the distance by the number.