WIRING

Beam  power  selection 

switch "H"

Beam  power  selection 

switch "L"

To detect human, install 

sensor at 2.6ft. to 3.3ft. 

(80cm to 100cm) height.

Select  beam  power  to  get  suitable  sensitivity  according  to 

protection distance.

PROTECTION DISTANCE

TERMINAL ARRANGEMENT

BEAM SPREAD RANGE

INSTALLATION HEIGHT

The  maximum  wire  length,  when  two  or 

more  units  are  connected,  is  the    above 

distance divided by the number of units.
The signal line can be wired to a distance 

of 3,280ft. (1,000m) with AWG 22 

(0.65mm dia.) wire.

Alarm output

24V (AC/DC) 

0.25A or less

N.C., N.O. 

selectable

Alarm output

selectable

switch

Tamper output

N.C.

30V (DC) 0.1A 

or less

Power supply 

10VDC

30VDC

 (non-polarity)

Power supply 

10VDC

30VDC

 (non-polarity)

Control panel

Control panel

Power

Power

Power

Alarm 

signal

Alarm 

signal (1CH)
Alarm 

signal (2CH)

Alarm 

signal

Control panel

(N.C. contact output)

(N.C. contact output)





TRANSMITTER

RECEIVER

WIRING DISTANCE

Example connection 1

Example connection 3

Example connection 2

33ft. (10m) or less

100ft. (30m) 

2.6ft. to 3.3ft.

(80cm to 100cm)

33ft. to 100ft.

(10m to 30m)

4.6ft. (

φ

1.4m)

TR.

TR.

TR.

RE.

TR.

RE.

TR.

RE.

RE.

RE.

N.C.

 ↑

 ↓

N.O.

AWG 22 (

φ0.65mm)

AWG 20 (

φ0.8mm)

AWG 18 

(

φ1.0mm)

AWG 17 (

φ1.1mm)

1,500ft.

(450m)

2,500ft.

(750m)

3,600ft.

(1,100m)

4,600ft.

(1,400m)

11,000ft.

(3,400m)

17,000ft.

(5,200m)

27,000ft.

(8,200m)

32,500ft.

(9,900m)

DC12V

DC24V

CONNECTION

Note 1)

2)

VOLTAGE

WIRE SIZE

① ②

① ②

①②

①②

①②

①②

①②③④

①②③④ ①②③④

①②③④

① ② ③ ④

① ② ③ ④   ⑤ ⑥