COVERAGE

3

INSTALLATION

4

(1)

84

°

68

°

38

°

21

°

10

°

22

° MIN. COVERAGE

MIN. COVERAGE

64°

44°

29°

19°

11°

22°

40' (12m)

5.25' (16m)

9.8' (3m)

WIDE ANGLE

PA-4810E

PA-4820E

LONG RANGE

40' (12m)

82' (25m)

82' (25m)

9.8' (3m)

9.8' (3m)

9.8' (3m)

(4)

(2)

Connect wires.

(3)

Attach the cover, and 
check operation.

Install the base on the wall. 
Knockout appropriate 
wiring and mounting screw 
holes.  Feed wire through 
knockout.

*Two mounting pitches are 

available for mounting to a 
single gang box.

*When installed on wall 

corner, make use of 4 
mounting knockouts on 
sides.

*Break the knockout and 

pull in the wire through it.  

 When using the upper 

wiring knockouts, route 
wires along wiring 
channel on either side

 (    portion) of plastic 

frame of P.C. Board.

Detach the cover. 
Loosen screw until 
cover slips.

CAUTION : Do not 
remove screw from 
cover. 
This will prevent locking 
nut from falling out and 
becoming lost.

TERMINAL ARRANGEMENT

1 2

3 4

6

8

7

POWER (non-polarity)
9.5V to 28V DC

TAMPER OUTPUT
Dry contact

ALARM OUTPUT
Dry contact
(semi-conductor)

N.C./N.O. selectable
Reset : approx. 2 sec.
30V DC (24V AC) 0.25A Max.
(Protective resistor 3.3

Ω

)

N.C. contact
Operation : Open when cover is detached.
30V DC 0.1A Max.

25mA Max.

LED Control

L/C

5

VACANT

BASIC CONNECTION

ALLOWABLE WIRING DISTANCE BETWEEN 

    SENSOR AND POWER SOURCE

Distance at 12VDC

Distance at 24VDC

Size of wire used

3800ft (1160m)

22000ft (  6700m)

5900ft (1800m)

34000ft (10400m)

AWG 22 (Dia.0.65mm)

AWG 18 (Dia.1.0mm)

AWG 16 (Dia.1.25mm)

9300ft (2840m)

55000ft (16500m)

HORIZONTAL 
ADJUSTMENT

VERTICAL 
ADJUSTMENT

Protrusion

Protrusion

AREA SETTING

ADJUST UNDER AIMING POSITION

ADJUSTMENT OF THE FIELD VIEW

6

WIRING

5

Sensor (N.C.)

Sensor (N.C.)

POWER

Signal Input

Adjust/check detection area visually in the following procedure when operation check shows improper area adjustment. 

visible

invisible

TAMPER

VACANT

L/C

POWER

ALARM

[When two units are used]

Note : 1) 

2)

Allow approx. one minute for warm-up after power is applied.  
(Alarm LED is flashing)  In the meantime, no alarm is initiated.

After the one minute has passed the unit will be in the armed 
condition and will trigger when detecting a human body.

When operation check shows improper area setting, check visually its area setting.

(1) Slide the head unit to bring the sensor 

unit into aiming position. Slip to the 
arrow direction and it will be 
automatically locked at testing position.

(2) Adjust the coverage by moving the 

mirror so that LED on the head unit is 
visible through mirror from location to 
be protected.

(3) After adjustment is completed, 

lightly push head unit. It will 
replace to the armed position 
automatically. 

When head unit is placed at 

testing position, alarm LED 
lights and alarm output 
continuously outputs (Trouble 
alarm).

You see a
mirror light
red.

parabolic mirror
(inside the sensor)

Adjust with 
parabolic mirror 
rotating by hands. 
Do not touch the 
mirror surface.

Hold parabolic 
mirror by hands 
and push for 
horizontal 
adjustment.

1

2

3

4

5

6

7

8

Maximum wiring distance, when two or more sets are 
connected, is the value above divided by numbers of 
sets.

The signal line can be wired to a distance of 3,280 ft 
(1,000m) with AWG 22 (0.65mm dia.) wire.