COVERAGE
3
INSTALLATION
4
(1)
84
°
68
°
38
°
21
°
10
°
22
° MIN. COVERAGE
MIN. COVERAGE
64°
44°
29°
19°
11°
4°
22°
40' (12m)
5.25' (16m)
9.8' (3m)
WIDE ANGLE
〈
PA-4810E
〉
〈
PA-4820E
〉
LONG RANGE
40' (12m)
82' (25m)
82' (25m)
9.8' (3m)
9.8' (3m)
9.8' (3m)
(4)
(2)
→
Connect wires.
(3)
Attach the cover, and
check operation.
Install the base on the wall.
Knockout appropriate
wiring and mounting screw
holes. Feed wire through
knockout.
*Two mounting pitches are
available for mounting to a
single gang box.
*When installed on wall
corner, make use of 4
mounting knockouts on
sides.
*Break the knockout and
pull in the wire through it.
When using the upper
wiring knockouts, route
wires along wiring
channel on either side
( portion) of plastic
frame of P.C. Board.
Detach the cover.
Loosen screw until
cover slips.
CAUTION : Do not
remove screw from
cover.
This will prevent locking
nut from falling out and
becoming lost.
【
TERMINAL ARRANGEMENT
】
1 2
3 4
6
8
7
POWER (non-polarity)
9.5V to 28V DC
TAMPER OUTPUT
Dry contact
ALARM OUTPUT
Dry contact
(semi-conductor)
N.C./N.O. selectable
Reset : approx. 2 sec.
30V DC (24V AC) 0.25A Max.
(Protective resistor 3.3
Ω
)
N.C. contact
Operation : Open when cover is detached.
30V DC 0.1A Max.
25mA Max.
LED Control
L/C
5
VACANT
{
{
{
{
【
BASIC CONNECTION
】
【
ALLOWABLE WIRING DISTANCE BETWEEN
SENSOR AND POWER SOURCE
】
Distance at 12VDC
Distance at 24VDC
Size of wire used
3800ft (1160m)
22000ft ( 6700m)
5900ft (1800m)
34000ft (10400m)
AWG 22 (Dia.0.65mm)
AWG 18 (Dia.1.0mm)
AWG 16 (Dia.1.25mm)
9300ft (2840m)
55000ft (16500m)
HORIZONTAL
ADJUSTMENT
VERTICAL
ADJUSTMENT
Protrusion
Protrusion
AREA SETTING
■
ADJUST UNDER AIMING POSITION
■
ADJUSTMENT OF THE FIELD VIEW
6
WIRING
5
Sensor (N.C.)
Sensor (N.C.)
POWER
Signal Input
Adjust/check detection area visually in the following procedure when operation check shows improper area adjustment.
●
visible
invisible
TAMPER
VACANT
L/C
POWER
ALARM
[When two units are used]
Note : 1)
2)
*
Allow approx. one minute for warm-up after power is applied.
(Alarm LED is flashing) In the meantime, no alarm is initiated.
*
After the one minute has passed the unit will be in the armed
condition and will trigger when detecting a human body.
When operation check shows improper area setting, check visually its area setting.
(1) Slide the head unit to bring the sensor
unit into aiming position. Slip to the
arrow direction and it will be
automatically locked at testing position.
(2) Adjust the coverage by moving the
mirror so that LED on the head unit is
visible through mirror from location to
be protected.
(3) After adjustment is completed,
lightly push head unit. It will
replace to the armed position
automatically.
*
When head unit is placed at
testing position, alarm LED
lights and alarm output
continuously outputs (Trouble
alarm).
You see a
mirror light
red.
parabolic mirror
(inside the sensor)
Adjust with
parabolic mirror
rotating by hands.
Do not touch the
mirror surface.
●
Hold parabolic
mirror by hands
and push for
horizontal
adjustment.
1
2
3
4
5
6
7
8
Maximum wiring distance, when two or more sets are
connected, is the value above divided by numbers of
sets.
The signal line can be wired to a distance of 3,280 ft
(1,000m) with AWG 22 (0.65mm dia.) wire.