The cut sections of the area masking sheet are the areas that are detected.
Once the sheet has been cut, it cannot be restored, therefore take care when 
cutting. 

When masking an area to one side (left or right areas), 
ensure that 2 masking sheets are attached to the 
corresponting portion of the lenses.

When masking of the detection area is completed, carry out a walk test to check that the detection area is suitable.

When using wall detection, ensure that the count setting is 
set to 1.

3-3

 Area Masking

3-4

 Area Confirmation

The default is a 180° detection area.

    Regardless of the settings of DIP switch 

6

, if DIP switch 

5

 is OFF, 

then the sensor will cover a 180° detection area.

1) Set DIP switches 

5

 and 

6

 to 

ON.

1) Without cutting the area 

masking sheet, mount the 
area masking sheet as is in 
the lens holder so that the 
opening is positioned at the 
edge of the lens.

2) As necessary, disable either 

the left or right side areas 
using mode setting switches.  

2) Confirm that only the left area 

is being activated.

To activate only the left area 
(disable the right area)

Preparation of the area masking sheet

To activate only the right area
 (disable the left area)

Example: To hide the left area zones 

 and 

.

Example: To hide the left area zones 

 and 

.

Reference diagram for masking

Bend the sheet to form a semicircle and fit inside of the cover's lens holder, then 
insert the cutout portion of the sheet into the tabs on the lens holder. 
(Mount so that the printed side of the sheet is on the inside.)

Cut along the perforations in the area masking sheet corresponding only to the 
areas for which detection is required.
Refer to the reference diagram for masking and cut the same numbers, and ensure 
that the same areas of both lenses are masked (using 2 masks) as a set.

Attach the area masking sheet

Right area

Cut out the areas required 
for detection.

Cut out the areas 
required for detection.

Area masking sheet ×2

Area masking sheet

Notch

Notch

Opening

Opening

Lens holder tabs

Lens holder tabs

Left area 
adjustment range

Right area 
adjustment range

Printed surface

Printed surface

Left area

[Wall detection]

s$ISABLETHERIGHTORLEFTDETECTIONAREA

  (by DIP switches 

5

 and 

6

, it is possible to disable 90° ranges to the left or right)

s5SINGTHEINCLUDEDAREAMASKINGSHEETCERTAINZONESCANBEELIMINATED

s&ORDETECTIONONESIDE

Mount the area 
masking sheet on all 4 
lenses as illustrated. 
(See DIP switch 5 to 
OFF.)

s&ORDETECTIONBOTHSIDES

[

5

 SETTING]

[

5

 SETTING]

[

5

 SETTING]

[

8

 WALK TEST]

[

5

 SETTING]

1) Set DIP switch 

5

 to ON, and 

6

 

to OFF.

2) Confirm that only the right 

area is being activated.

[

5

 SETTING]

Sensor

Sensor

Left

area

Right

area

Left

area

Right

area

ON

OFF

5 6

ON

OFF

5 6

ON

OFF

5 6

Содержание OMS-12FE

Страница 1: ...bber enables detection of interference with the sensor such as attempts to remove it from the mounting surface 7 INSTALLATION 5 Support for mounting on poles optional pole attachment Use of the option...

Страница 2: ...uld result in injury or damage Do not connect devices that exceed the capacitance as shown on the output terminal Doing so may cause fire Do not use the sensor in bathrooms or other locations with hig...

Страница 3: ...difference Install the unit at the height of g M TO g M FROM the ground Do not install the unit by an air conditioning exhaust vent Remove all obstructions TREES CLOTHESLINES ETC Do not install the se...

Страница 4: ...stance When using at 12m distance 3 3 1m 3 3 1m 3 3 1m 3 3 1m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 3 3 1m 15 3 16 5 5...

Страница 5: ...Reference diagram for masking Bend the sheet to form a semicircle and fit inside of the cover s lens holder then insert the cutout portion of the sheet into the tabs on the lens holder Mount so that...

Страница 6: ...ver installation procedure Move the knockout tab on the rear of the sensor left and right and twist off Attach the back tamper rubber Take care with the mounting direction Additionally after attachmen...

Страница 7: ...be adjusted in accordance with the environment and intended purpose Normally use medium 100 Setting the sensitivity to 170 will trigger detection even at small changes in temperature Use this in stabl...

Страница 8: ...f the outside and inside sensor knockouts to use then feed the wiring through the wiring hole and connect to the terminals For external wiring Wiring from above Wiring from below Wiring hole Wiring bo...

Страница 9: ...35mm 2 Mounting pitch 7 56 197mm Pole mounting bracket 2 Pole mounting bracket screws 4 3 Place the optional fixing bracket around the pole and fix the sensor to the pole with the pole bracket and sc...

Страница 10: ...water droplets 3 Unsuitable detection or pulse count settings 1 Readjust detection area 3 DETECTION AREA 2 After wiping with a damp soft cloth wipe off water droplets 3 Ensure appropriate detection a...

Страница 11: ...in 9 to 28V DC non polarity 20mA MAX Dry contact relay output N C N O selectable Contact capacity 30V AC DC 0 2A MAX Resistive load Contact operation Detection time 2sec Dry contact relay output N C C...

Страница 12: ...eng co jp Takex America Inc 230E Caribbean Drive Sunnyvale CA 94086 U S A Tel 408 747 0100 Fax 408 734 1100 http www takex com Takex Europe Ltd Takex House Aviary Court Wade Road Basingstoke Hampshire...

Отзывы: