We appreciate your purchase of a TAKEX passive infrared sensor.  This sensor will provide long and dependable service when properly 
installed.  Please read this Instruction Manual carefully for correct and effective use.

Please Note

 : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device. 

                        TAKEX is not responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive     
                        surge by lightning), abuse, misuse, abnormal usage, faulty installation or improper maintenance.      

Instruction Manual

 OMS-12FE

This product is a passive sensor that can be used both indoors and outdoors, and that detects the far infrared radiation given off by body heat.  
Using this sensor with other products enables a variety of applications, such as giving notifications of visitors or waring in the detection of intruders.

Main Features

[

3

 DETECTION AREA]

[

4

 FUNCTION]

(2) Selection of area corresponding to intended 
      purpose

(1) Dual Zone system

(3) Rainproof housing

(4) Back Tamper

Use of the provided back tamper rubber enables detection of 
interference with the sensor, such as attempts to remove it 
from the mounting surface.

[

7

 INSTALLATION]

(5) Support for mounting on poles 
     

 (optional pole attachment)

Use of the optional pole attachment enables mounting on 
poles with a diameter of 1.49" to 1.77" (38mm to 45mm).

s5SINGTHEINCLUDEDAREAMASKINGSHEETENABLESPARTIAL

  masking of zones for which detection is not required.

 IEC standard: IP54 compliant.

Approximately 180°

 

φ

1.49" to 1.77" 

(38mm to 45mm)

Downwards zone

 Horizontal zone

Detected

Detection range

Not detected

Dual Zone Outdoor PIR

s4HESENSORWATCHESA

wide, 180° angle, meaning 
that a single unit can 
cover a wide range.

s4HISSENSORISEQUIPPEDWITHA$5!,:/.%SYSTEM

which initiates an alarm only when detection occurs in 
both the horizontal and downward zones simultaneously. 
This prevents false alarms for distant automobiles or for 
small animals.

s"YCHANGINGTHEANGLEOFTHEDOWNWARDSZONEITIS

POSSIBLETOCHANGETHEDETECTIONDISTANCE$ISTANTVEHICLES

that do not enter the downwards zone are not detected.

Small animals that do not enter the horizontal zone are 

not detected. Similarly, birds and other objects that only 
enter the horizontal zone are also not detected.

s!ªZONEEITHERTOTHELEFTORRIGHTCANBEDISABLED

Содержание OMS-12FE

Страница 1: ...bber enables detection of interference with the sensor such as attempts to remove it from the mounting surface 7 INSTALLATION 5 Support for mounting on poles optional pole attachment Use of the option...

Страница 2: ...uld result in injury or damage Do not connect devices that exceed the capacitance as shown on the output terminal Doing so may cause fire Do not use the sensor in bathrooms or other locations with hig...

Страница 3: ...difference Install the unit at the height of g M TO g M FROM the ground Do not install the unit by an air conditioning exhaust vent Remove all obstructions TREES CLOTHESLINES ETC Do not install the se...

Страница 4: ...stance When using at 12m distance 3 3 1m 3 3 1m 3 3 1m 3 3 1m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 33 10m 40 12m 0 16 5 5m 3 3 1m 15 3 16 5 5...

Страница 5: ...Reference diagram for masking Bend the sheet to form a semicircle and fit inside of the cover s lens holder then insert the cutout portion of the sheet into the tabs on the lens holder Mount so that...

Страница 6: ...ver installation procedure Move the knockout tab on the rear of the sensor left and right and twist off Attach the back tamper rubber Take care with the mounting direction Additionally after attachmen...

Страница 7: ...be adjusted in accordance with the environment and intended purpose Normally use medium 100 Setting the sensitivity to 170 will trigger detection even at small changes in temperature Use this in stabl...

Страница 8: ...f the outside and inside sensor knockouts to use then feed the wiring through the wiring hole and connect to the terminals For external wiring Wiring from above Wiring from below Wiring hole Wiring bo...

Страница 9: ...35mm 2 Mounting pitch 7 56 197mm Pole mounting bracket 2 Pole mounting bracket screws 4 3 Place the optional fixing bracket around the pole and fix the sensor to the pole with the pole bracket and sc...

Страница 10: ...water droplets 3 Unsuitable detection or pulse count settings 1 Readjust detection area 3 DETECTION AREA 2 After wiping with a damp soft cloth wipe off water droplets 3 Ensure appropriate detection a...

Страница 11: ...in 9 to 28V DC non polarity 20mA MAX Dry contact relay output N C N O selectable Contact capacity 30V AC DC 0 2A MAX Resistive load Contact operation Detection time 2sec Dry contact relay output N C C...

Страница 12: ...eng co jp Takex America Inc 230E Caribbean Drive Sunnyvale CA 94086 U S A Tel 408 747 0100 Fax 408 734 1100 http www takex com Takex Europe Ltd Takex House Aviary Court Wade Road Basingstoke Hampshire...

Отзывы: