③
* Use the pole attachment BP-32 sold separately.
(for pole dia 38mm to 45mm (1.50" to 1.77"))
(1) Break off the pole mounting knockouts.
(2) Fit the pole mounting brackets to the sensor.
(3) Select Active or Inactive Back Tamper by reversing the rubber switch cover.
(4) Use sealant to caulk the screw hole and the gap around wiring entry.
(5) Fit the pole fixing bracket around the pole and fix the sensor with screws.
(6) Make sure that the sensor is not inclined when viewed in front or laterally.
Make sure that sealant is used to caulk the
wiring hole and screw hole.
Power voltage
Size of wire used
12V DC
24V DC
AWG22 0.3mm
2
(
φ
0.65mm)
AWG20 0.5mm
2
(
φ
0.8mm)
AWG18 0.8mm
2
(
φ
1.0mm)
AWG16 1.3mm
2
(
φ
1.3mm)
Wire size: AWG24
〜
AWG16 (0.2mm
2
〜
1.3mm
2
)
Maximum wiring distance
=Value of Power voltage / Number of sets
Max. signal line distance: 1,000m (3,000ft.)
(with AWG 22 (dia. 0.65mm) telephone wire)
NOTE: 1)
2)
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
POWER
ALARM OUTPUT (1)
ALARM OUTPUT (2)
TROUBLE OUTPUT
TAMPER OUTPUT
: 9 to 28V DC (non-polarity) Current consumption 30mA max.
: N.C./N.O. selectable, 30V (AC/DC) 0.2A max. (Resistive load)
: N.C./N.O. selectable, 30V (AC/DC) 0.2A max. (Resistive load)
(For EXTERNAL OUTPUT : N.O. only)
: N.C. 30V (AC/DC) 0.2A max. (Resistive load)
: N.C. 30V (AC/DC) 0.1A max. (Resistive load)
①
②
32:(5
③
④
$/$50
$/$505,*+7
$/$50/()7
⑤
⑥
$/$50
(;7(51$/
287387
⑦
⑧
7528%/(
⑨
⑩
7$03(5
Mode setting “A-2” OFF
Mode setting “A-2” ON
$/$50
5,*+7/()7
3ROHPRXQWLQJ
EUDFNHW
%3
.QRFNRXW
.QRFNRXW
.QRFNRXW
.QRFNRXW
:LULQJKROH
6FUHZKROH
6FUHZKROH
4-1
Terminal configuration
4-2
Wiring distance
3-3
Pole mount
350m (1100’)
550m (1800’)
850m (2800’)
(4600’)
1400m
1700m (5600’)
2800m (9200’)
4400m (14500’)
7100m (23000’)
:,5,1*