background image

Model

MX-12FAMD

Detection system

Passive infrared

 and Microwave

Detection area

Horizontal detection

Angle : 180°, Detection distance : 12m(40')
Horizontal zone : 14 zones     Downward zone : 14 zones

PIR Area adjustment

Detection distance : 2 to 12m(10' to 40') [10 ranges]
(by adjusting vertical angle of downward curtain)

Supply voltage

9 to 28V DC (non-polarity)

Current consumption

Alarm output (1)

Alarm output (2)

40mA max.

ALARM RIGHT+LEFT 

ALARM RIGHT 

ALARM LEFT

EXTERNAL OUTPUT

Tamper output

Dry contact relay output N.C.
Contact capacity : 30V (AC/DC) 0.1A max.(Resistive load)

Trouble output

Dry contact relay output N.C.
Contact capacity : 30V (AC/DC) 0.2A max.(Resistive load)

Operation LED

Red LED

Warm-up  (Blinking)

Alarm detection  (Lights approx.2sec only for Walk test)

Low supply voltage  (Blinking slowly)

Masking detection  (Blinking rapidly)

Self diagonosis error  (Lights continuously)

Dry contact relay output N.C./N.O. selectable

Contact capacity : 30V (AC/DC) 0.2A max. (Resistive load)

Contact operation : Detection time (+2sec.)

Dry contact relay output N.C./N.O. selectable

Contact capacity : 30V (AC/DC) 0.2A max. (Resistive load)

Contact operation : Detection time (+2sec.)

Dry contact relay output N.O.

Contact capacity : 30V (AC/DC) 0.2A max. (Resistive load)

Contact operation : Detection time (+30sec. latch time)

Pulse count

1  / 3  times (selectable with DIP switch)

PIR sensitivity adjustment

60% / 80% / 100% / 120% (selectable with DIP switch, left and right sensors individually)

Functions

Anti-masking, Microwave environment, Back tamper, Trouble alarm, Low voltage monitoring
Anti-masking Environmental level

Connection

Terminals

Ambient temperature

-25°C to + 60°C (-13°F to + 140°F)

Mounting position

Indoor / Outdoor

Ingress protection

IP55 (Wall mount)

Weight

400g (14.2oz)

Optional

Pole attachment : BP-32

Appearance

Body : resin (white) / Lens : resin (white)

left and right adjustment individually possible

(Cover tamper / Back tamper (when enabled))

(Masking detection / Low supply voltage / Self diagonosis error)

 

Specifications and design are subject to change without prior notice.

Short / Long

Microwave
range adjustment

Green LED

Microwave alarm detection

 (Lights max.2sec only for Walk test)

Microwave transmit
frequency and power

24.150 to 24.250GHz 12.7dBm  e.i.r.p

(selectable with DIP switch, left and right sensors individually)

MAINTENANCE

1. Clean the device with a soft, damp cloth and wipe off water drops. Use water with weak neutral detergent to clean stubborn

dirt. (except lens)
Do not use substances such as thinner or benzene. 

2. Perform operation check on a regular basis.

63(&,),&$7,216

Содержание MX-12FAMD

Страница 1: ...glass 1RW GHWHFWHG E 3 5 Thank you for your purchase of this TAKEX dual zone outdoor PIR This sensor will provide a long and dependable service when properly installed Please read this Instruction Ma...

Страница 2: ...it to the terminals 3 Use sealant and caulk the gap around the wiring External wiring 1 Break off the desired knockout before wiring 2 Feed the wiring through the wiring hole and connect it to the te...

Страница 3: ...2 1 3mm Wire size AWG24 AWG16 0 2mm2 1 3mm2 Maximum wiring distance Value of Power voltage Number of sets Max signal line distance 1 000m 3 000ft with AWG 22 dia 0 65mm telephone wire NOTE 1 2 POWER A...

Страница 4: ...rizontal zone Detection range Detection range Horizontal zone Detected Detected Not detected RUL RQWDO RQH RUL RQWDO RQH RZQZDUG RQH UDQJHV RZQZDUG RQH UDQJHV LEFT SENSOR RIGHT SENSOR 3 5 3 5 3 5 3 5...

Страница 5: ...asking 5 3 Switch setting 6KRUW RQJ 6KRUW RQJ 02 6 77 1 21 2 DFWRU VHW 02 6 77 1 2 RIGHT SIDE LEFT SIDE 0 52 9 19 0 52 9 19 RIGHT SIDE LEFT SIDE MODE SETTING A MODE SETTING B 21 2 21 DFWRU VHW 6 257 2...

Страница 6: ...l noise broadcasting station amateur radio station etc is nearby 4 Direct or reflected light such as sunlight or headlights sometimes shines onto the sensor itself or into the detection area 5 The sen...

Страница 7: ...put N O Contact capacity 30V AC DC 0 2A max Resistive load Contact operation Detection time 30sec latch time Pulse count 1 3 times selectable with DIP switch PIR sensitivity adjustment 60 80 100 120 s...

Страница 8: ...KL LUX LJDVKLQR DPDVKLQD NX RWR DSDQ 7HO 2DNODQG 5G 6XLWH 6DQ RVH 86 7HO D Limited Warranty TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original...

Отзывы: