background image

Accessory

6HOIWDSSLQJVFUHZ

SFV

$UHDPDVNLQJVKHHW

SFV

)ROGHGDQGVWRUHG

LQVLGHWKHFRYHU

&RYHU

/HQV

2SHUDWLRQ
/('

&RYHU/RFNLQJVFUHZ

0RGHVHWWLQJ%

'LVWDQFH

DGMXVWPHQW

OHYHU

:LULQJKROH

0RXQWLQJKROH

0RXQWLQJKROH

Loosen the cover locking screw and remove the cover.

(6) Fix the sensor using the supplied screws.

[Embedded wiring ]

  (1) Align the back of sensor with the wiring from the wall.

  (2) Feed the wiring through the wiring hole and connect it to the terminals.

  (3) Use sealant and caulk the gap around the wiring.

[External wiring ]

  (1) Break off the desired knockout before wiring.

  (2) Feed the wiring through the wiring hole and connect it to the terminals.

  (3) Use cable conduit and joint boxes to cover the wiring.

  (4) Use sealant to caulk the gap around the wiring.

  (5) Select Active or Inactive back tamper by reversing the rubber switch cover.

$FWLYH)DFWRU\VHW

,QDFWLYH

%DFN7DPSHU

Make sure that sealant is used to caulk the 
wiring hole and gaps.

%DFNWDPSHU

7HUPLQDOV

.QRFNRXW

.QRFNRXW

3-1

 Before mounting

3-2

 Wall mount

0RGHVHWWLQJ$

WRP
WR

',3VZLWFK

',3VZLWFK

3$576'(6&5,37,21

,167$//$7,21

Содержание MX-12FAMD

Страница 1: ...glass 1RW GHWHFWHG E 3 5 Thank you for your purchase of this TAKEX dual zone outdoor PIR This sensor will provide a long and dependable service when properly installed Please read this Instruction Ma...

Страница 2: ...it to the terminals 3 Use sealant and caulk the gap around the wiring External wiring 1 Break off the desired knockout before wiring 2 Feed the wiring through the wiring hole and connect it to the te...

Страница 3: ...2 1 3mm Wire size AWG24 AWG16 0 2mm2 1 3mm2 Maximum wiring distance Value of Power voltage Number of sets Max signal line distance 1 000m 3 000ft with AWG 22 dia 0 65mm telephone wire NOTE 1 2 POWER A...

Страница 4: ...rizontal zone Detection range Detection range Horizontal zone Detected Detected Not detected RUL RQWDO RQH RUL RQWDO RQH RZQZDUG RQH UDQJHV RZQZDUG RQH UDQJHV LEFT SENSOR RIGHT SENSOR 3 5 3 5 3 5 3 5...

Страница 5: ...asking 5 3 Switch setting 6KRUW RQJ 6KRUW RQJ 02 6 77 1 21 2 DFWRU VHW 02 6 77 1 2 RIGHT SIDE LEFT SIDE 0 52 9 19 0 52 9 19 RIGHT SIDE LEFT SIDE MODE SETTING A MODE SETTING B 21 2 21 DFWRU VHW 6 257 2...

Страница 6: ...l noise broadcasting station amateur radio station etc is nearby 4 Direct or reflected light such as sunlight or headlights sometimes shines onto the sensor itself or into the detection area 5 The sen...

Страница 7: ...put N O Contact capacity 30V AC DC 0 2A max Resistive load Contact operation Detection time 30sec latch time Pulse count 1 3 times selectable with DIP switch PIR sensitivity adjustment 60 80 100 120 s...

Страница 8: ...KL LUX LJDVKLQR DPDVKLQD NX RWR DSDQ 7HO 2DNODQG 5G 6XLWH 6DQ RVH 86 7HO D Limited Warranty TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original...

Отзывы: