168
OPTIONS
Biodegradable oil
Biodegradable oil is a new type of hydraulic oil that is decomposed into carbon dioxide and
water by microorganisms in the soil and water. It is highly safe for living organisms and offers
advantages in terms of environmental protection.
�
Recommended biodegradable oil: Mobile EAL Envirosyn 46H (an ester synthetic oil).
When replacing the hydraulic oil with biodegradable oil, use the above or an equivalent
oil. Note that other oils, even other brands of ester synthetic oils, may damage O-rings,
packings and seals. Takeuchi products shipped with the optional biodegradable oil are
shipped with the above brand of oil.
�
When switching from a mineral oil to a biodegradable oil, the parking brake torque
decreases by about 30%.
Replacing the hydraulic oil with biodegradable oil
Mixing mineral oil with biodegradable oil will result in a decrease of the hydraulic oil’s
performance as well as a decrease in biodegradability and safety. The hydraulic oil system
must be flushed as described below before supplying the biodegradable oil. This operation
is dangerous and requires experience. Have it performed by a Takeuchi sales or service
outlet.
Flushing
To be performed by a Takeuchi sales or service outlet
1. Drain the hydraulic oil (mineral oil) from the hydraulic tank and Clean the inside of the tank
and suction strainer.
Refer to page 124 “Replacing the Hydraulic Oil and Cleaning the Suction Strainer”.
2. Remove the cylinder hoses and drain the hydraulic oil (mineral oil) from inside the
cylinders.
3. Supply new biodegradable oil to the hydraulic tank.
4. Bleed the air from the pump and cylinders and pressurize the hydraulic tank.
5. Operate the hydraulic devices for 30 minutes.
6. Drain the biodegradable oil from the tank and cylinders.
7. Replace the hydraulic oil return filter with a new filter.
8. Repeat steps 3 and 4.
9. Operate the hydraulic devices for 30 minutes.
10. Drain the biodegradable oil from the tank and cylinders.
11. Repeat steps 3 and 4.
12. Operate the hydraulic devices for 1 hour.
13. Drain the biodegradable oil from the tank and cylinders.
14. Replace the return filter with a new filter.
15. Repeat steps 3 and 4.
16. Operate the hydraulic devices, then check for oil leakage.
There is no need to flush the hydraulic oil system when switching from biodegradable to
mineral hydraulic oil.
Biodegradable Oil
Содержание TB23R
Страница 6: ...4...
Страница 8: ...6...
Страница 35: ...33 SAFETY Safety Signs Decals...
Страница 36: ...34 SAFETY Safety Signs Decals...
Страница 150: ...148...
Страница 151: ...149 SPECIFICATIONS Main Speci cations 151 Machine Dimensions 152 Operating Range 154 Lifting Capacities 157...
Страница 152: ...150 MEMO...
Страница 154: ...152 SPECIFICATIONS Machine Dimensions...
Страница 156: ...154 SPECIFICATIONS Operating Range...
Страница 158: ...156 MEMO...
Страница 164: ...162...
Страница 175: ...173 MEMO...
Страница 182: ...180...
Страница 183: ...181 INDEX...