5 LICENSE MANAGEMENT
5.3 Enabling Temporary Authentication
27
5
5.3
Enabling Temporary Authentication
This section shows the method for enabling the temporary authentication of an option driver.
By enabling the temporary authentication, an option driver can be used before acquiring a license file.
Operating procedure
1.
Select [Online]
[Manage MES Interface Module] in MES Interface Function Configuration Tool.
2.
Select a target option driver body in "Option Driver List" in the [Option Driver Management] tab.
3.
Click the [Temporary Authentication] button.
Precautions
• If there is a time difference between CPU No.1 on the own station and a configuration personal computer, temporary
authentication cannot be enabled. In this case, match the time between them and enable the temporary authentication
again.
• The effective period of temporary authentication is 14 days regardless of the time when it is enabled.
(Example) If it is enabled on November 1, 2019, it will be expired at 00:00 on November 15, 2019.
• The expiration date of temporary authentication is calculated in local time.
• Temporary authentication can be enabled only once for an MES interface module per option driver. Make sure that a target
MES interface module is correct by checking the product information in advance. (The product information must match that
of an MES interface module for which a license file is to be acquired.)