![Takara Belmont AY-CU-SX1 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/takara-belmont/ay-cu-sx1/ay-cu-sx1_operating-instructions-manual_814510024.webp)
□Turn the water on and check it visually that
the water is output from the shower head
properly, that there are no water leakage
from the water outlet or base of the shower
head and that the hot water is not tainted.
□If there is water leakage from the water outlet or
base of the shower head, the internal packing
may be worn and replacement is necessary.
(see page 15)
□ Is water output
from
the shower
head
properly?
□If hot water is not output properly or is cloudy,
the check valve strainers may be dirty. Clean
the check valve strainers. (see page 26,27)
□If the water sprays in random directions from
several holes, the spray nozzle may be blocked
with the water scale or dirty. Remove the spray
nozzle and clean them. (see page 25)
24
Procedures for Daily Inspections
To ensure that this product can be used for a long period of time, conduct the inspections below.
■Inspect the product every day
Inspection item
Inspection method
□Can you pull the
basin open and
close smoothly
□When you pull the basin open and close,
be sure not to be holded or strange noise.
□Check that the there is no obstacles
between the back or side of the basin box
and basin body.
□It may cause deformed or damage the basin
box and the basin body. Remove obstacles and
check whether pulling the basin box open and
close smoothly.
□It may cause malfunctions or deformed or
damaged owing to opening and closing defect .
If you don’t find defect in the back or side of the
basin box, stop using the product.
□Is there any water
on the basin body
□Check that there is no any water except the
basin and the inner of the basin body.
□It may cause the product to damage and a stain
may not quite come off. Wipe off the water
immediately except the basin and the inner of
the basin body.
□Is there strange
smell from the
inside of the basin.
□Pull the basin box open and check that
there is no strange smell from the
drainage.
□There may be obstacles or dirty on the surface
of the inner panel and drainage in the inner
panel.Check and clean them.
(see page 15)
□There may be obstacles or dirty in the hair
catcher. Open the maintenance door off and
check it.
If there is obstacles or dirty, clean them.
(see page 16)
□Visually check it around the platform
installation surface below the basin to see
if there is any water leakage.
□Take the maintenance door off and check
that there is no water leak inside the
platform.
□Is there any water
leakage from the
basin installation
surface?
□The water may leak from inside the basin. Open
the maintenance door and check inside, and
stop using the product immediately if there is
water leakage.
□ Does the tap work
propery.
□Turn on and off the tap(in the case of
double tap type, turn it), check it hot
water is output properly and there is no
strange noise.*An strange gushing sound
may be emitted as water flows)
□If there is strange noise or the water does not
turn off properly when turn off the tap
complately,
there may be malfunctions in the
water regulator.
□Turn the tap (in the case of double tap type,
temperature control knob)and check if hot
water is output properly and that there is
no strange noise. *An strange gushing
sound may be emitted as water flows)
□If you can’t adjust temperature properly or there
is strange sound, there may be a malfunctions
of the temperature control knob.
If the inspection results show defects
Содержание AY-CU-SX1
Страница 26: ...26 MEMO...
Страница 27: ...27 MEMO...