background image

11

Fastening the Face Guard to the Hood

*The side with the crossed strap is the top part and
  the side with the strap to be fastened by the ends 
  is the bottom part.

Resin cord side

Face the side with the seam 
to the front when installing. 

Align it with the
center of the Hood.

2. Turn on the Power Switch.

Turning on the power switch a few minutes before use 
will shorten the time up to the generation of mist.

ON

OFF

Woven Cord Side

2. Attaching the Face Guard to 
    the inside frame of the Hood.

This installation can be eased by using the 2 tabs 
in the upper section of the frame and covering from 
top to bottom.

3. Tighten the strap in the bottom 
    section of the Face Guard.

Adjust the upper section strap (the resin cord side) position so 
that it comes to the front edge of the Hood.
Open up the strap in the upper section sufficiently 
to accommodate the customerís head.

Turn on the power

1. Insert the power plug in the electrical outlet.

1. Loosen the strap at the bottom
    (the woven cord side) of the 
    Face Guard.

Caution

Do not connect another electrical 
appliance to the same outlet.
Push the power plug all the way in to 
secure it.
Remove the plug at the end of the 
workday or when the steamer will not 
be used for a length of time.

Содержание Ak-200

Страница 1: ...sily referred to when necessary Contents Usage Safety Cautions and Warnings 2 Assembly Instructions 5 6 Location of Warning Labels Specifications 4 Component Parts 7 Control Panel 8 Positioning the Un...

Страница 2: ...ernal section gets hot during operation and may cause burns if touched If a foreign body falls into the internal section turn off the power and contact our service center or sales office Keep hands an...

Страница 3: ...oloration Do not move the main unit using the Nape Bar This may lead to the unit tipping over and may cause damage to the Nape Bar Do not apply force to the Hood This may lead to the unit tipping over...

Страница 4: ...e Main Unit 3 After putting back the Water Container turn on the power If the indicator is no longer showing of OF you can start operation If the indication is still displayed after performing the mea...

Страница 5: ...ix the Base Stand AY 200 in position with the bolt and tool 1 Attach the accompanying Support Cap in the direction shown in the illustration Main Unit Hood Side Depression Depression Cutout Support Ca...

Страница 6: ...Be sure to remove the washer and sleeve Leaving them attached to the Support may cause damage to the product 4 Loosen the Height Adjustment Knob Be sure that the main unit can be moved up and down 3 A...

Страница 7: ...Water Container Handle Water Container Holder Water Container Cap Drain Cock Main Unit Front Handle Power Switch Face Guard Nape Pad Height Adjustment Knob Nape Bar Main Unit Section Power Cord Drain...

Страница 8: ...Control Panel Level Mist Amount Lamp Color Yellow Red start stop Key Use this to start the operation of each mode Use this to stop operation Pressing the start key after a mode has been exited will r...

Страница 9: ...ding on usage The Standard Hood Internal Temperature is the temperature at approximately 5 minutes after the start of operation In operation over long periods of time the actual temperature may be sli...

Страница 10: ...the Water Container Cap and add the water Caution Caution Always purify tap water before using it Use either water from the accompanying Takara Water Purifier TJ 5 or water that has been specifically...

Страница 11: ...be eased by using the 2 tabs in the upper section of the frame and covering from top to bottom 3 Tighten the strap in the bottom section of the Face Guard Adjust the upper section strap the resin cor...

Страница 12: ...ter part of the back of the turban Move the Main Unit to behind the customer Towel Turban Height Adjustment Knob Turban Rear Center Section 2 Open the upper cover and lower the Hood while checking the...

Страница 13: ...en it is at Temperature Level 0 Thus the operations described above should not be attempted In these cases the display does not indicate a malfunction Turn off the power switch and then turn it on aga...

Страница 14: ...e the machine is paused Changing conditions while paused Press the key that corresponds to the setting to be changed Operating Time Mist Level Temperature Level Cooling Enabled Disabled Change Operati...

Страница 15: ...peration has ended the Unattended Time including the cleaning time will be displayed by flashing it on and off Fastener Removing the Face Guard 1 Open the Upper Cover 2 Press on the fastener button an...

Страница 16: ...k water Remove the Drain Tank at the front of the Main Unit and discard the water accumulated in it 1 Raise the Hood 2 Move the Cock that keeps the Drain Tank in place to an upright position 3 Grasp t...

Страница 17: ...ould be wiped clean periodically Hair stuck inside or chemicals may cause malfunctions and become a source of foul odors When treatment permanent or coloring chemicals come into contact with the unit...

Страница 18: ...r in the Water Container Operation will resume after water has been added Indicates an excess of water 1 Turn off the Power Switch 2 Remove the Water Container and discard the water in the Main Unit 3...

Страница 19: ...ake sure that the Power Switch has been turned on Make sure that the power plug is properly plugged into the outlet No mist comes out If the display is blinking p 18 p 18 If the display is blinking If...

Страница 20: ...Memo 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...

Отзывы: