9
Wall Hanging Installation
The TKJr is built for wall mount installations only.
Use proper screws to secure the unit in place.
Locate the heater as desired, but follow all
applicable local codes, as well as the indoor or
outdoor clearances that apply to the installation.
Outdoor Installation
Follow all local codes, or in the absence of local
codes, follow the codes for Installation of Gas
Burning Appliances; National Fuel Gas Code ANSI
Z221.23 in USA or CAN/CGA B149.1 or .2 in
Canada.
For outdoor installation, purchase a TK-TV04 and
install on the top of the unit.
Locate the water heater in an open, unroofed area,
and maintain the following minimum clearances
from combustible and noncombustible materials.
Outdoor Clearances
Bottom (Piping side)
6”
Front (Maintenance space)
Min. 6”
Back of heater
1”
Non piping side (in enclosed closet)
2”
Non Piping side (open area)
12”
Top of heater
36” from
overhang
If this unit is installed under an overhang, there
must be a 36” clearance from the top of the unit to
the overhang, and the surrounding area must be
open in front and on the sides of the unit.
WARNING
:
Do not have the flue terminal pointing
toward any opening into a building. Do not locate
your heater in a pit or any location where gas and
water can accumulate.
WARNING
:
Do not install the heater where water,
debris, or flammable vapors may get into the flue
terminal. This may cause damage to the heater.
Содержание T-KJr
Страница 7: ...6 Wiring Diagram...
Страница 17: ...16 This system will also need a pump of 1 12 hp or greater depending on the application situation...
Страница 24: ...23 Case Burner Gas Manifold...