background image

Installation 

 

 

 

 

 

General 

 

All gas water heaters require careful and correct 
installation to ensure safe and efficient operation. 
This manual must be followed exactly. 
 
1. Read the For Your Safety section in the 

beginning of this manual. 

2.  This unit is not capable of being used as a pool 

or spa heater. 

3.  The regulator is preset at the factory. It is 

computer controlled and should not need 
adjustment. 

4.  Suitable for potable water heating only.  Well 

water or hard water may cause scale problems 
that will not be covered by the manufacturer’s 
warranty. 

5.  Maintain proper space for servicing. Install the 

unit so that it can be connected or removed 
easily. 

6.  Install so that the electrical power can be 

switched off if necessary. 

7.  Avoid installing in an area with high levels of 

dust, sand or debris. Particles may clog the air 
vent, reduce fan function, or cause improper 
combustion.

 

 

8.  Do not install the unit where the exhaust vent 

is pointing into any opening in a building or 
where the noise may disturb your neighbors. 

Accessories 
 

Check that all the parts listed below were  

This section is for the installer. The installer is 
responsible for the correct installation of your 
Flash Water Heater. 

For Your Safety: 

Only a certified and trained service technician 
or qualified plumber may service or install 
your product.

 

included with the unit. 

 

Please keep this owner’s manual in a safe 
place for future reference. Copies of this 
manual are available from TAKAGI-USA 

 

Electrical Connections 

The T-K1 requires a 60 Hz 120 VAC electrical 
power supply, and it should be properly grounded 
in accordance with the most recent edition of the 
National Electrical Code, ANSI/NFPA 70 and any 
local codes. In Canada, all electrical wiring to the 
heater should be installed in accordance with the 
Canadian Electrical Code, CSA C22.1 Part 1, and 
any local codes. Do not rely on the gas or water 
piping to ground the metal parts of the heater. 

 
CAUTION

: Label all wires prior to disconnection 

when servicing controls. Wiring error can cause 
improper and dangerous operation.  Verify proper 
operation after servicing. 
 

• 

A means for switching off the 120 VAC power 
supply must be provided.

 

• 

Wire the heater exactly as shown in the wiring 
diagram.

 

• 

A green screw is provided in the junction box 
for the grounding connection. Refer to the 
following wiring diagram. Wiring diagrams are 
also printed on the inside panel of the 
appliance 

 

 

 

5

Содержание T-K1

Страница 1: ...tes carbon monoxide gas and flue gases which can cause serious injury or death Improper installation and or operation or installation by an unqualified person will void warranty ng WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors or liquids in the ...

Страница 2: ...K RE01 20 TK BK01 20 TK TV01 20 TK TV03 20 Exploded Diagram 21 Parts List 22 Flow Charts 23 Specifications Natural Gas Input Min 37 000 Btu Max 165 000 Btu LPG Input Min 35 000 Btu Max 165 000 Btu Gas Connection NPT Water Connections NPT Water Pressure Min 15 psi Max 150 psi Natural Gas Pressure Inlet Min 5 WC Max 10 5 WC LP Gas Pressure Inlet Min 11 WC Max 14 WC Manifold Pressure Natural 3 5 WC P...

Страница 3: ...n the Gas Company or the manufacturer WARNING Do not disconnect the electrical supply if the temperatures will be near freezing The Freeze Prevention Device will only work if the unit has proper electrical power The Freeze Prevention Device is rated for temperatures down to 5º F 15º C in a wind free environment The wind chill factor will cause the Flash Water Heater to freeze and be damaged at tem...

Страница 4: ...h water heater 1 Open a hot water tap or turn on water demanding appliance 2 Unit will detect flow burners will ignite Fire On lamp will light up 3 If necessary mix in cold water to get a comfortable temperature Turning It Off To turn off the Flash water heater 1 Close the hot water tap or turn appliance off 2 Flow will diminish unit will shut off 3 Fire On lamp will go out Temperature The output ...

Страница 5: ...t install the water heater in an area with extremely cold weather This will void your warranty and Takagi Industrial Co USA Inc will not be responsible for any damage that occurs WARNING The pipe heaters are located on the Flash Water Heater only Any hot or cold water pipes located outside of the unit will not be protected Properly protect and insulate these pipes from freezing If the heater will ...

Страница 6: ...aller The installer is responsible for the correct installation of your Flash Water Heater For Your Safety Only a certified and trained service technician or qualified plumber may service or install your product included with the unit Please keep this owner s manual in a safe place for future reference Copies of this manual are available from TAKAGI USA Electrical Connections The T K1 requires a 6...

Страница 7: ...Rating 120 VAC 60 Hz 0 8 A Note If any of the original wiring supplied with this appliance must be replaced it must be replaced with appliance wiring material 180c or its equivalent Wires are available through the manufacturer 6 ...

Страница 8: ...our gas type Always install a manual shutoff valve on the gas supply line in case of an emergency or if service or maintenance is necessary This appliance and its individual shut off valve must be isolated from the gas supply piping system by unplugging the unit and turning off the main gas valve during any pressure testing of the gas supply piping system at test pressures equal to or less than PS...

Страница 9: ... hot line out of the unit with no check valves or control valves between the unit and the relief valve The Pressure relief valve must be rated for 150 PSI and have a discharge capacity of 165 000 BTU Connect the discharge opening of the relief valve to a suitable drain to prevent water damage should discharge occur If the pressure relief valve discharges periodically this may be due to thermal exp...

Страница 10: ...nding area must be open in front and on the sides of the unit Use the included L brackets to connect the unit to a wall to ensure that it does not fall over These brackets will maintain the required 1 clearance between the back of the unit and a combustible surface WARNING Do not have the flue terminal pointing toward any opening into a building Do not locate your heater in a pit or any location w...

Страница 11: ...r installation safety features WARNING Do not install the unit directly on a combustible surface such as carpeting wood floors etc If it is necessary to install the unit standing on a surface install a 3 noncombustible base between the unit and the surface Indoor Installation Follow all local codes or in the absence of local codes follow the codes for Installation of Gas Burning Appliances Nationa...

Страница 12: ...ed through a wall use Takagi USA Inc optional part the TK TV01 vent terminator or an equal Category III vent part Locate the vent terminator according to ANSI Z223 1 NFPA 54 and applicable local codes Maintain the following clearances to any combustible surface in an indoor installation Indoor Clearances Piping side 6 Front Maintenance space Suggested 24 Min 4 Floor Noncombustible base Back of hea...

Страница 13: ... SMELL GAS Do not use any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Initial Operation 1 STOP Do not operate without reading the safety information first 2 Switch off the electrical power supply to the...

Страница 14: ...for space heating at temperatures higher than required for other used a means such as a mixing valve shall be installed to temper the water for those uses in order to reduce scald hazard potential Water temperature over 125 F can cause severe burns instantly or death from scalds Chemicals such as diluted Glycol can be used for radiant floor Hydro warm air or Baseboard heating only Basic system dra...

Страница 15: ...eboard heating equipments Warning Follow all local codes or in the absence of local codes follow the most recent edition of the National Standard Code ANSI Z21 10 3 Warning This illustration is for concept only There are a wide variety of variations to the application of controls and equipment presented applications Designers must add all necessary safety and auxiliary equipment to conform to code...

Страница 16: ...y to achieve higher flow rates for longer periods of time then it can be installed in conjunction with a storage tank A pump will be necessary to keep the water hot and it should be controlled by an Aquastat set at 120 F max with a 10 F differential We suggest a pump of 1 12 hp or greater depending on the system Recirculation This system will need a pump controlled by an aquastat Set aquastat at 9...

Страница 17: ...ater heater area for evidence of leaking gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach you...

Страница 18: ...ldren or the infirm without supervised Vapors 1 Cannot be seen 2 Vapors are heavier than air 3 Go a long way on the floor 4 Can be carried from other rooms to the main burner by air currents Keep flammable products 1 Far away from heater 2 In approved containers 3 Tightly closed 4 Out of children s reach DANGER Hot Water Heater temperature over 125 F can cause severe burns instantly or death from ...

Страница 19: ...g according to the chart first check that the gas supply line is sized properly and that the gas pressure is within the required range If the gas line is okay check the plumbing for mixing valves thermostatic valves scald protection single handled valves or crossed connections If the unit is performing in accordance with the flow chart then it may be undersized for the application It Takes Too Lon...

Страница 20: ...Lower No Problem Possible parts to check 11 Igniter Computer Igniter Flame rod gas valve gas resource 12 Burner flame Computer Flame rod gas valve gas resource Blinking Off 72 Pre post check Computer Flame rod gas valve gas resource 14 Computer gas valve hi limit switch Computer hi limit switch gas valve Off Blinking 71 Computer gas valve Computer gas valve Blinking Together 45 Fan motor Computer ...

Страница 21: ...1 is going to be vented out through a wall This is a CSA approved part of the unit Connect a Category III Stainless vent pipe from the top of the unit to the backside of this terminator to exhaust flue gases through the wall without a thimble Install vent terminator in accordance with manufacturer s installation instructions and any applicable local codes 4 TK TV03 Vent Cap The TK TV03 Vent Cap is...

Страница 22: ...21 ...

Страница 23: ...IXING PLATE 27 OVER HEAT CUT OFF FUSE 28 HEAT EXCHANGER FIXING PLATE 29 FUSE FIXING PLATE 30 HEATER BLOCK ASSEMBLY 31 HEATER FIXING PLATE 32 HI LIMIT SWITCH 33 THERMISTOR ASSEMBLY 34 FLOW SENSOR 35 WATER GOVERNOR CASE 36 WATER GOVERNOR 37 WATER INLET 38 O RING 39 O RING 40 O RING 41 O RING 42 O RING 43 JOINT PACKING 44 FILTER 45 WATER OUTLET 46 DRAIN PLUG 47 DRAIN BAND 48 DRAIN PLUG 49 DRAIN BAND ...

Страница 24: ...t Temperature 40 F 3 9 3 6 3 4 3 2 3 0 2 9 2 7 50 F 4 5 4 2 3 9 3 6 3 4 3 2 3 0 60 F 5 4 4 9 4 5 4 2 3 9 3 6 3 4 70 F 6 8 6 0 5 4 4 9 4 5 4 2 3 9 110 115 120 125 130 135 140 23 Ground Water Temperature vs Hot Water Flow Rate 0 0 1 0 2 0 3 0 4 0 5 0 6 0 Inlet Ground Water Temperature to 140 F Outlet Hot Water Out Flow Rate with 140 F GPM 2 7 2 9 3 0 3 2 3 4 3 6 3 9 4 2 4 5 4 9 5 4 40 45 50 55 60 65...