- 17 -
Common Trouble Shooting
The T-M1 can burn gas at a maximum input
rate of 235,000 BTUH. This puts a limit on the
possible output temperature and flow
capabilities. If the water doesn’t seem hot
enough, compare the flow and temperature
that is being attained to the T-M1 flow vs.
temperature chart (See flow chart on the last
page of this manual). If the unit is not
performing according to the chart, first check
that the gas supply pipe is sized properly and
that the gas pressure is within the required
range. If the gas line is sized properly, check
the plumbing for mixing valves, thermostatic
valves, anti-scald devices, single handled
faucets with built in temperature or pressure
compensators valves and hot and cold crossed
connections. If the unit is performing in
accordance with the flow chart, it may be
undersized for the application. If the unit is
performing according to the chart, the output
temperature can be adjusted using the TM-
RE10 or the dipswitches on the unit.
It Takes Too Long to Get Hot Water
The T-M1 takes three seconds to ignite and
three more seconds to heat the incoming
ground water up to the set temperature. The
time it takes to deliver hot water from the T-M1
to your fixtures depends on the length of piping
between the two. The longer the distance, the
more time it will take. If you would like to
receive hot water to your fixtures quicker, you
may want to consider a hot water recirculation
system.
The T-M1 Will Not Initiate
First check the flow rate through the unit. If the
flow is less than .75 GPM, the unit will not
initiate. Check the filter for any debris or
damage. If you have installed a combination
system (a T-M1 doing both domestic hot water
and space heating), completely isolate the
heating system temporarily to ensure flow is
not backfeeding through your heating system
to supply the domestic water (by-passing the
T-M1).
If neither of those remedies start the unit, press
the lower green button marked “test (off)” on
the GFCI inside the unit. If the red light above it
does not come on, there is a problem with the
electrical supply to the unit. If that red light
does come on, hit the “reset (on)” button and
open a hot water faucet to re-try the unit. If the
problem persists contact Takagi for instructions
ERROR CODES
All Takagi units are self diagnostic for safety
and convenience when trouble shooting. If
there is a problem with the installation or the
unit, it will display a numerical error code on
the TM-RE10 (if installed) or at the bottom left
corner of the computer board to communicate
the source of the problem. Consult the
following chart for the cause of an error code:
The T-M1 consists of five major control
operations: Temperature control, Gas control,
Water control, Burner Control, and Main
computer control
.
Error Symptom Error
Symptom Error
Symptom
031
Wrong Gas Type
331
Mixing Thermistor Fail
701
Abnormal Computer Board
101
Insufficient Gas
Supply
391
Abnormal
Thermocouple
711
Abnormal Gas Solenoid
Valve
111
Ignition failed
441
Flow Sensor
721
Computer Pre-post Check
Problem
121 Loss
Flame 510
Abnormal Main Gas
Valve
741
Main remote control
Trouble
141
Hi-Limit Switch Trip
541
Abnormal Two-Way
Valve
751
Temperature Remote
control Trouble
211
Vent Pipe
611
Abnormal Fan Motor
761
Multi-system Controller
311
Output Thermistor
Fail
651
Abnormal Output Adjust
Valve
991 Abnormal
Burning
321
Inlet Thermistor
Fail
661
Abnormal Bypass Valve
Содержание Mobius T-M1
Страница 28: ... 28 128 127 126 123 9 125 124 122 119 120 117 121 118 115 116 115 114 111 18 112 113 ...
Страница 29: ......
Страница 30: ... 30 1 2 3 4 5 6 2 3 7 8 9 10 11 12 13 3 ...
Страница 34: ... 33 MM1097 126 ...