GAS SUPPLY AND GAS PIPE SIZING 

Check  that  the  type  of  gas  matches  the  rating 

plate located on the cover of your water heater. 

The  minimum  and  maximum  inlet  gas  pressures 

are:

Natural Gas  Min. 5.5” WC - Max. 10.5” WC

Propane Gas  Min. 9.5” WC - Max. 14” WC 

Gas  pressure  below  this  specified  range  for  the 

T-KJR  and/or  insufficient  gas  volume  will 

adversely affect performance.  Inlet gas pressure 

must not exceed the above maximum values; gas 

pressure  above  the  specified  range  will  cause 

dangerous  operating  conditions  and  damage  to 

the unit. Until testing of the main gas line supply 

pressure is completed, ensure the gas line to the 

T-KJR  is  disconnected  to  avoid  any  damage  to 

the water heater. 

Size  the  gas  pipe  appropriately  to  supply  the 

necessary volume of gas required for the T-KJR 

(140,000  BTUH)  using  ANSI233.1/NAPA  54  in 

the USA or CAN/CSA B149.1 in Canada or local 

codes.  Install  a  manual  gas  shut-off  valve 

between  the  T-KJR  and  the  gas  supply  line.   

When  the  gas  connections  are  completed,  it  is 

necessary  to  perform  a  gas  leak  test  either  by 

applying  soapy  water  to  all  gas  fittings  and 

observing  for  bubbles  or  by  using  a  gas  leak 

detection  device.    Always  purge  the  gas  line  of 

any  debris  before  connecting  to  the  heater  gas 

inlet.

Pipe  Sizing  Example:

  This  table  below  is  for 

Natural  gas  piping  supply  straight  to  the  water 

heater without any tabs to other gas appliances 

Recommend Gas pipe size for 

T-KJR Water Heater(Example for NG)

Distance from Gas Meter  Pipe Size (inches) 

0' - 60' 

3/4" 

60' - 150' 

1" 

150' – 300’ 

1-1/4" 

1.  Turn  off  all  electric  power  to  the 

water  heater  if  service  is  to  be 

performed.

2.  Turn the manual gas valve located 

on the outside of the unit clockwise 

 to the off position. 

A.  This water heater does not have a 

pilot.    It  is  equipped  with  an 

electronic  ignition  device  that 

automatically lights the burner.  Do 

not try to light the burner manually;

B.  BEFORE  OPERATING,  check  all 

around  the  water  heater  area  for 

gas  leaks.    Be  sure  to  check  next 

to  the  floor  as  some  gases  are 

heavier  than  air  and  will  settle  on 

the floor; 

C.  Use only your hand to turn the gas 

valve knob. Never use tools. If the 

knob  will  not  turn  by  hand,  do  not 

attempt to repair it. Call a qualified 

service  technician.  Force  or 

attempted repair may result in a fire 

or explosion. 

D.

WARNING:

 Conversion of this unit 

from  natural  gas  to  propane  or 

propane  to  natural  gas  cannot  be 

done in the field. Contact your local 

distributor to get the correct unit for 

your gas type. Conversion done by 

anyone 

other 

than 

the 

manufacturer will void all warranty

.

TO TURN OFF GAS TO  

APPLIANCE

FOR YOUR SAFETY, READ 

BEFORE OPERATING: 

Содержание Flash Water Heater T-KJr

Страница 1: ...injury or death In addition if the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death T KJr Instantaneous Water Heater Installation Manual and Owner s Guide Flash Water Heater Model T KJr Suitable for potable water heating and space heating FEATURING ENDLESS HOT WATER ON DEMAND COMPACT SPACE SAVING ENERGY CONSERVING CO...

Страница 2: ...l Gas Pressure Inlet Min 5 5 WC C W 5 0 1 x a M LP Gas Pressure Inlet Min 9 5 WC C W 4 1 x a M Manifold Pressure Natural 3 2 WC C W 2 3 e n a p o r P s b l 2 3 t h g i e W Dimensions 20 x14 x6 Ignition Electronic Ignition Electrical Supply AC 120 V NOTE Check the rating plate to ensure this product matches your specifications This appliance is certified for use at altitudes from 0ft to 4500ft 1 37...

Страница 3: ...on It is advisable to open further the cold tap rather than decreasing the hot tap to adjust the water temperature As long as you have water gas and electricity you will get an endless flow of hot water Open a hot water tap to turn on your water heater Close the tap to turn off your water heater FOR YOUR SAFETY PLEASE READ THIS MANUAL CAREFULLY AND FOLLOW ALL DIRECTIONS 1 Follow all local codes or...

Страница 4: ... Following the diagram below when installing your water heater GENERAL The T KJR Water Heater is an instantaneous tankless water heater designed to supply endless hot water to your entire household and or commercial facility utilizing total efficiency The principle behind the T KJR Water Heater is simple Once you open a hot water tap water flows through the T KJR Water heater Once a minimum of 0 7...

Страница 5: ...e the noise may disturb your neighbors Make sure the vent termination is 4 feet from a doorway or opening to prevent exhaust from entering 7 Some chemicals used in a beauty salon may affect the flame sensor Water heater may not work properly Please consult with Takagi when the water heater is installed in a beauty salon 8 Water hardness may affect the water heater Water heater may be damaged The w...

Страница 6: ...red clearances around the unit Combustion Air Supply The water heater location must provide enough air for proper combustion and ventilation of the surrounding area See the latest edition of ANSI Standard Z223 1 or any applicable local codes In general these requirements specify that if the unit is installed in a confined space there must be a permanent air supply opening Air Supply from Outside B...

Страница 7: ... latest edition of the Natural Fuel Gas Code ANSI Z223 1 and all applicable local building codes In Canada follow section 7 of the CAN CSA B149 1 Natural Gas and Propane Installation Code Exhaust Vent This is a Category III appliance and must be vented accordingly The vent system must be sealed air tight All seams and joints must be sealed with high heat resistant silicone sealant or UL listed alu...

Страница 8: ...ossible to the vent terminator 2 The vent collar of the water heater must be fastened directly to an unobstructed vent pipe 3 Do not weld the vent pipe to the water heater collar 4 The weight of the vent stack must not rest on the water heater 5 The vent must be easily removable from the top of the water heater for normal service and inspection of the unit 6 The water heater vent must not be conne...

Страница 9: ...o t e c n a r a e l C G r e n r o c e d i s n i o t e c n a r a e l C H Clearance to each side of center line extended above meter regulator assembly 3 feet I Clearance to service regulator vent outlet 3 feet J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other application 3 feet 1 foot 4 feet from below or side opening 1 foot from above opening K Cle...

Страница 10: ...efore connecting to the heater gas inlet Pipe Sizing Example This table below is for Natural gas piping supply straight to the water heater without any tabs to other gas appliances Recommend Gas pipe size for T KJR Water Heater Example for NG Distance from Gas Meter Pipe Size inches 0 60 3 4 60 150 1 150 300 1 1 4 1 Turn off all electric power to the water heater if service is to be performed 2 Tu...

Страница 11: ...ch as one having an anti backflow device in the cold water supply line a thermal expansion tank must be installed Contact the water supplier or local plumbing inspector on how to control this situation After installation of the water heater is complete purge the water line to remove all the debris and air from the line Failure to do so may cause damage to the heater There is a wire mesh filter wit...

Страница 12: ...alve is required This unit does not come with an approved pressure relief valve An approved pressure relief valve must be installed on the hot water outlet The pressure relief valve must conform to ANSI Z21 22 or CAN 1 4 4 and installation must follow local code The discharge capacity must be at least 140 000 BTU hr The discharge piping for the pressure relief valve must be directed so that the ho...

Страница 13: ...ng only your hand to avoid any spark Never use tools If the knob will not turn by hand do not try to force it call a qualified service technician Force or attempted repair may result in a fire or explosion due to gas leaks Be sure to check next to the bottom of the unit because some gases are heavier than air and may settle towards the floor CAUTION IF YOU SMELL GAS 1 Do not try to start the water...

Страница 14: ...testing water heater output the T KJR is rated for 179 gallons per hour GPH or 3 0 gallons per minute GPM when raising the water temperature by 77 F for example from 43 F to 120 F Refer to the following chart of typical household plumbing fixture flow rates to determine what the FLASH T KJR can do in a household application Lamp is lit Lamp is lit extinguished Household Flow Rates Appliance Use Fl...

Страница 15: ...r Heater the output hot water temperature can be adjusted either manually from the main computer board s dipswitches or with the optional remote controller Part TK RE02 from 99 F to 167 F The dipswitches can set four hot water output temperatures 113 F 122 F 140 F and 182 F the factory set temperature is 122 F could damage the temperature controller and or the water heater which will void the warr...

Страница 16: ...r operation after servicing The FLASH T KJR water heater requires an electrical power supply from 120 VAC 60 Hz circuit and be properly grounded A means for switching on off the 120 VAC power supply must be provided for service reasons Wire the heater exactly as shown in the wiring diagram A green screw is provided in the junction box for grounding connection MAINTENANCE AND SERVICE WARNING Turn o...

Страница 17: ...Initiate First check the flow rate through the unit If the flow is less than 75 GPM the unit will not initiate Check the filter for any debris or damage If you have installed a combination system a T KJR doing both domestic hot water and space heating completely isolate the heating system temporarily to ensure flow is not backfeeding through your heating system to supply the domestic water by pass...

Страница 18: ...pped with an ignition device that automatically lights the burner Do not try to light the burner by hand B BEFORE OPERATING smell all around the water heater area for evidence of leaking gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use an...

Страница 19: ...e children or the infirm without supervised DANGER Hot Water Heater temperature over 125 F can cause severe burns instantly or death from scalding Children disabled and elderly are at the highest risk of being scalded Feel water temperature before bathing or showering Temperature limiting valves are available ask professional person DANGER Keep flammable products 1 Far away from heater 2 In approv...

Страница 20: ...s water for space heating at temperatures higher than required for other uses a means such as a mixing valve shall be installed to temper the water for those other uses in order to reduce scald hazard potential Water temperature over 125 F can cause severe burns instantly or death from scalds Chemicals such as diluted Glycol can be used for radiant floor Hydro fan coil air or Baseboard heating onl...

Страница 21: ...s follow the most recent edition of the National Standard Code ANSI Z21 10 3 Warning This illustration is a concept design only The reference to the 1 8th hole in check is only for the State of Massachusetts There are a wide variety of variations to the application of controls and equipment presented Designers must add all necessary safety and auxiliary equipment to conform to code requirements an...

Страница 22: ...ure for longer periods of time then it can be installed in conjunction with a storage tank A pump will be necessary to keep the storage tank water hot We suggest a high head pump of 1 12 hp or greater depending on the system Recirculation This system will also need a high head pump of 1 12 hp or greater depending on the application situation ...

Страница 23: ... as helping to prevent the unit from freezing in areas where cold air can be blown or drawn into the exhaust system Install this vent damper in accordance with Takagi s installation instructions and any applicable codes 4 TK TV04 Vent Cap The TK TV04 Vent Cap is for outdoor installation with the T KJr water heater The cap is installed on the top of the unit instead of connecting an exhaust vent pi...

Страница 24: ...24 Component Diagram Case Heat Exchanger Computer ...

Страница 25: ...25 Gas Manifold Water Way ...

Страница 26: ...3 SCREW 124 FAN 125 PRESSURE SWITCH SENSING PLATE 126 SILICONE TUBE 127 EXHAUST PACKING 128 SCREW 129 OVERHEAT CUT OFF FUSE FIXING PLATE 130 OVERHEAT CUT OFF FUSE 131 OVERHEAT CUT OFF FUSE FIXING PLATE 132 HI LIMIT SWITCH 133 SCREW 134 SCREW 401 HEAT EXCHANGER ASSEMBLY 402 O RING 403 FREEZE PROTECTION HEATER 404 FREEZE PROTECTION HEATER PLATE 405 WATER INLET 406 INLET DRAIN PLUG 407 O RING 408 FIL...

Страница 27: ... Output Hot Water GPM 40 F 50 F 60 F 70 F 40 F 4 6 4 2 3 8 3 5 3 3 3 1 2 9 2 7 2 6 2 4 2 3 2 1 1 9 1 8 1 8 1 7 1 6 50 F 5 7 5 1 4 6 4 2 3 8 3 5 3 3 3 1 2 9 2 7 2 6 2 3 2 1 2 0 1 9 1 8 1 8 60 F 5 7 5 1 4 6 4 2 3 8 3 5 3 3 3 1 2 9 2 6 2 3 2 2 2 1 2 0 1 9 70 F 5 7 5 1 4 6 4 2 3 8 3 5 3 3 2 9 2 6 2 4 2 3 2 2 2 1 90 95 100 105 110 115 120 125 130 135 140 150 160 165 170 175 180 ...

Страница 28: ......

Отзывы: