22
T-KJr. with Storage Tank
The maximum flow rate through the T-KJR is 5.8 GPM. If it is necessary to achieve higher
flow rates with full pressure for longer periods of time, then it can be installed in conjunction
with a storage tank. A pump will be necessary to keep the storage tank water hot. We
suggest a
high-head
pump of 1/12 hp or greater depending on the system.
Recirculation
This system will also need a
high-head
pump of 1/12 hp or greater, depending on the
application situation.