43
Page
Troubleshooting
Owner's Guide
Remote Green LED Malfunction
description
Diagnosis
651
Four Flashes
Flow adjustment
valve fault (Only
Easy-Link & Multi-Unit
System)
•
Inspect the flow adjustment valve (Part #402), for
connection/breakage of wires, locked motor drive due to
scale buildup, and/or water leakage.
661*
Four Flashes
Bypass valve fault
(510C model only)
•
Inspect the bypass valve (Part #403), for connection/
breakage of wires, locked motor drive due to scale
buildup, and/or water leakage.
701*
One Flash
Computer board fault
•
Check for connection/breakage of wires (Part #713).
711*
One Flash
Gas solenoid valve
drive circuit failure
•
Refer to the 111 and 121 error codes.
721*
Six Flashes
False flame detection
•
Check if condensate drain is installed on the vent collar of
the water heater.
•
Check if there is leaking from heat exchanger (Part #401).
741
N/A
Miscommunication
between water heater
and remote controller
•
Check the model type of the remote controller.
•
Inspect the connections between the water heater and
remote controller.
•
Check the power supply of the water heater.
751
N/A
Miscommunication
between water
heater and built-in
controller
•
Inspect the connections between the water heater
and built-in controller.
•
Check the power supply of the water heater.
761
N/A
Miscommunication in
Easy-Link system
•
Check if the connections between the parent unit and the
child units are correct. Refer to p. 25.
991
Five Flashes
Imperfect
combustion
•
Check the gas type of the water heater.
•
Inspect the environment around the water heater.
Determine how long the unit has been installed.
•
Check the altitude/elevation of the area of where the
water heater is installed.
•
Check if there is any blockage in the intake air and/or
exhaust.
•
Check to make sure that there is enough distance between
the concentric vent terminal and other exhaust vent ter-
minals.
•
Check if there is grease and/or dirt in the burner (Part
#101) and the fan motor (Part #103), especially if the
water heater has been installed in a contaminated area.
*These error codes will be cleared when water flow stops.