It is possible to detect the wiring in a building by broadcasting the Transmitter signal into the
wiring. For searching, use the External coil, supplied as an option, which is connected to the
Signal input terminal (8-pin connector ) of the Receiver.
Receiver
Connect the External coil's plug to the Signal Input Terminal (8-pin connector)
on the Receiver
Transmitter
Set the frequency same as the Receiver.
The clips are connected to the transmitter.
Tracing the wire
Connect the External
coil's plug
‘
+
’ appears
Set a frequency on the receiver
same as the External coil.
Receiving Sensitivity
Hold the External coil near the wall as illustrated.
The coil in the External coil attachment picks up the signal and the current
strength (=receiving sensitivity level) is displayed on the LCD.
Note: The depth is not displayed.
Always check that the Transmitter, the
Receiver and the External coil are at the
same frequency.
Press Frequency. key.
Press FREQUENCY. key.
Connect the red clip to the
conductor on the plug.
Connect the Black clip
to a ground stak
e.
ELECTRIC SHOCK
Death or serious injury will result. 250 Volts maximum across clips.
DANGER
Neutral
A stiff piece
of wire
Coil needs to be
perpendicular to wire
+