![TAKACHIO MPL-H11S Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/takachio/mpl-h11s/mpl-h11s_manual_814296011.webp)
- 11 -
Various settings
1. Selects backlight options. By pressing Mode , move on.
2. Selects sound options. By pressing Mode , move on.
3. Selects Depth function. By pressing Mode , move on.
4. Selects Gain control operation. By pressing Mode , return to measurement.
5. Selects PROBE detection.
By pressing Mode , return to measurement.
When Sewer or Mini Probe is employed for the detection of Non-metallic pipe or Boring device,
38kHz, 512Hz
and
850Hz
are used for Probe.
*The last setting is saved except Depth function.
Press
Gain
: Select speaker sound On / Off.
Press
Gain
: Select depth function 0-5m / 0-30m ( 0-16ft / 0-99ft.).
Press
Gain
: Select detecting function .
Mode
CAUTION
When applying Inductive mode, select 0-5m /16ft . Depth measurement
error gets bigger at near the Transmitter when 0-10m/30ft is applied.
PROBE OFF
.
Cable / Pipe detection
PROBE ON
.
Probe detection
Press
Gain
: Select backlight On / Off.
SOUND ON (Small)
SOUND OFF (Large)
SOUND OFF
LIGHT ON
LIGHT OFF
*0-5m / 16ft :
Applied for Inductive mode.
Detecting near t he end of the pipe.
Depth measurement range 0 to 5m(16ft).
*
0-30m / 99ft :
Applied for the depth deeper than
5m(16ft.) , near guardrail or metal fence.
The measurement range of depth
0 to 10m(30ft).
(See page 9)
Press
Gain
: Select Gain
control operation
MANU GAIN
AUTO GAIN