3-Sep 2021 Ver.0.91
TAIYO YUDEN CO., LTD.
TAIYO YUDEN CO., LTD.
36/198
EYSKJNAWB-VX
3.3 Application Settings and Defaults
The table below lists the user-configurable settings and their default values
以下の表でユーザー設定項目とデフォルト値を示します。
Table 4: Application defaults
Field
Value
Field
Value
UART Baudrate
115200
Conn interval max
200ms
Regulator
LDO
Conn super timeout
4s
LFCLK
Internal RC
Conn Latency
0
Device name
“Tysa-B 5XXXX”
XXXX: address 2 Bytes
Extended primary PHY
0
– 1Mbps
Role
Peripheral
Extended second PHY
2
– 2Mbps
Address type
1 (random static)
IO capabilities
0
– None
Address
Factory default
Scan window
250ms
Advertising interval
100ms
Scan interval
500ms
Advertising duration
10s
Scan duration
10s
Advertising mode
1
Scan type
active
Advertising data
Device name only
Scan device name filter
“Tysa-B 5”
Autostart
Enabled
Scan Service UUID filter
disabled
Bonding
Enabled
Scan RSSI filter
disabled
Conn interval min
100ms
Scan data filter
disabled
Auto Device name
Enabled
Scan address filter
disabled
Security level
1
– None
Accept list
disabled
3.4 Saving Configuration Data
Configuration data is read from non-volatile Flash memory during boot and stored in volatile memory
(RAM) during operation. Configuration changes made by the user only updates the values stored in
volatile memory, therefore any reset or loss of power will cause these changes to be lost. Users can
issue a
Save
command (
SAVE
) to the EYSKJNAWB-VX to commit the current configuration data to
Flash. This command can only be issued while the device is not currently advertising, scanning or
connected via BLE. When this command is successfully executed, the previous configuration will be
erased and the new configuration stored. Upon completion, a
save (SAVE)
event will be issued to the
user interface. In the event that the data is not correctly written or the device is reset before the save
completes, the EYSKJNAWB-VX will attempt to recover the configuration data during boot. If the
recovery fails, the default configuration will be loaded.
設定データは起動時に
Flash
から読み出され動作中に
RAM
に格納されます。設定変更は、通常
Memory(RAM)
に保存されている値のみを更新するため、リセットまたは電源が切れると変更した内
容が失われます。
SAVE
コマンドを使用して最新の設定情報を
Flash
に保存することで、リセットま
たは電源が切れても設定値を保持することができます。このコマンドは、デバイスが通信
(Advertising/
スキャン
/BLE
接続
)
を行っていない間のみ使用することができます。このコマンドが正常に実行され
た場合、実行前の設定情報は削除され新しい設定情報が保存されます。保存が完了すると、フラッシ
ュ操作(
FLOK
)イベントがユーザーインターフェースを介して出力されます。データが正しく書き
込まれないか、保存が完了する前にデバイスがリセットされた場合、
EYSKJNAWB-VX
は起動中に設
定データを回復しようとします。リカバリが失敗すると、デフォルト設定がロードされます。