7. The troubleshooting and elimination of machine

Sequence 

number 

Faults

Causes

Action

The motor is out of 
operation 

1. The power supply is

disconnected.

2. The contactor of control

motor can not work.

3. The startup head (NO)

of motor damaged.

1. Check the power supply

line for soundness,
especially the zero line.

2. Check the contactor and

repair or replace it.

3. Check the switch and

repair or replace it.

The motor rotates 
reversely. 

The two phase lines of 
motor are connected 
reversely. 

Interchange the external two 
phase lines of motor. 

The motor can 
rotate when the 
startup button is 
pressed and stop 
when released. 

The contactor of motor has 
been broken or the head 
has been broken. 

Check the contactor or 
switch and repair or replace 
it. 

The motor stops 
suddenly during 
normal operation. 

The thermal relay is 
released and current is 
overloaded. 

Check the thermal relay, 
readjust or replace it. 

The handle switch 
is not pressed and 
the rocker arm 
descending. 

There are errors in handle 
switch and solenoid valve. 

Check the handle switch 
contact and valve, repair or 
replace it. 

The rocker arm 
can not descend 
when the handle 
switch is pressed. 

1. There is error in manual

switch.

2. There is no sufficient oil

amount in oil tank.

3. There is leakage in

hydraulic oil pipe or
joint.

4. The relief valve is

loosed.

5.

Switches are not

pressed
synchronously by
hands.

6. The solenoid valve can

not work.

7. The  seal  ring  is  broken

or the wearing is 

1. Check, repair or replace it.
2. Add hydraulic oil of the

same type.

3. Check oil pipe and joints

to eliminate faults.

4. Readjust the relief valve.
5.

Press

again

synchronously.
6. Check the electromagnet

or surrounding wires.

7. Check  seal  ring  or  oil

cylinder and eliminate
faults as per condition.

6

Содержание TW-510A

Страница 1: ...MANUAL FOR PATENT STYLE SWING ARM CUTTING MACHINE TW 510 512 516 A B C SERIES ...

Страница 2: ...y please read this operation instruction carefully Only when the structure performance and working principle of this machine are completely understood the functions of this machine can be fully utilized and the service life of this machine can be lengthened 1 ...

Страница 3: ...f machine 4 The function and debugging of machine control element 5 The operation order of machine 6 The maintenance and service of machine 7 The troubleshooting and elimination of machine 8 Hydraulic Schematic Diagram 9 Electric Diagram 10 Components Illustration 2 ...

Страница 4: ... delay circuit is adopted to control the low limit position of stroke providing higher precision and cutting quality The hand wheel can be used adjust the height of working table of rocker arm distance featuring more simple reliable and convenient 4 Main key parts both the main post and the piston of oil cylinder adopt high quality steel 5 The inertia of flywheel can realize instantaneous cutting ...

Страница 5: ...or to observe whether the rotation direction of the flywheel is in accordance with the clockwise direction Carry out test punching for several times with empty load after idling for two minutes 3 6 Press the OFF button of motor the power indictor will be off and the machine stops 4 The function and debugging of machine control element 4 1 Set the delay timer in the minimum position 4 2 Place the m...

Страница 6: ...t once per week The oil filter must be cleaned once per month Suggestion Raise the main post to the maximum position and clean it Blow off pollutants from inside to outside with compressed air during cleaning of oil filter 6 2 Hydraulic oil level It is necessary to check the oil level in machine body in application of machine If it is lower than the minimum position the hydraulic oil of the same t...

Страница 7: ...nly during normal operation The thermal relay is released and current is overloaded Check the thermal relay readjust or replace it 5 The handle switch is not pressed and the rocker arm descending There are errors in handle switch and solenoid valve Check the handle switch contact and valve repair or replace it 6 The rocker arm can not descend when the handle switch is pressed 1 There is error in m...

Страница 8: ...ir them as per checking results 8 The blanking has been cut off but the cutting depth of knife die is too large The motor rotate slowly and even stops 1 The delay time is too long 2 The relief valve is loosed and the pressure of overflowed liquid is low 3 The solenoid valve can not be reset 1 Reset a shorter time 2 Readjust the pressure 3 Repair or replace it 9 The rocker arm can not be reset afte...

Страница 9: ...8 Hydraulic Schematic Diagram 8 ...

Страница 10: ...9 Electric Diagram For TW 510 512 516 9 ...

Страница 11: ...9 Electric Diagram For TW 510C 512C 516C 10 ...

Страница 12: ...er and the missing one can not be supplemented It will be invalid if altered and become worthless when expired 4 Note Product with one of the following conditions will not be guaranteed but it can be maintained with charge The valid invoice or guarantee repair list can not be offered There are modifications on invoice or guarantee repair list and the products on guarantee repair list can not compl...

Страница 13: ...10 Components Illustration 12 ...

Страница 14: ...10 Components Illustration 13 ...

Страница 15: ...10 Components Illustration 14 ...

Страница 16: ...10 Components Illustration 15 ...

Страница 17: ...10 Components Illustration 16 ...

Страница 18: ...10 Components Illustration 17 ...

Страница 19: ...10 Components Illustration 18 ...

Отзывы: