Power Supply Description
MBZ-00001-01
November 2004
Copyright © 2004 Tait Electronics Ltd
Mains power to the PSU module is supplied via an IEC plug on the rear panel and the
illuminated power switch on the front panel (refer to Figure 2.1). This path is filtered.
The mains ground line is connected directly to the T809-10 chassis (stud terminal), and
from there to the module’s ground terminal.
The PSU module’s output is filtered by a ferrite sleeve, and then interfaces to the rack
through a Phoenix Contact Feed-through terminal block on the T809-10 rear panel.
For the wiring diagram, refer to Section 6.2.1.