![Tailift TPR1100 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/tailift/tpr1100/tpr1100_operation-manual_813882019.webp)
3-4
3.4 Electric system calculation
3.4.1 For TPR-720A, TPR-820A, TPR-920A
Motor Part Name
Rated Power Capacity
Maximum Initiate Power
Main Motor
1.5kw
4.2kw
Elevating Motor
0.75kw
2.1kw
Coolant Pump Motor
0.1kw
0.28kw
Total Rated Power Capacity:
(1.5kw+0.75kw+0.1kw)=2.35kw…………………..(1)
Maximum Total Initiate Power Capacity:
(4.2kw+2.1kw+0.28kw)=6.58kw………………….. (2)
Transformer Rated Output Power Capacity for Control Circuits
Model
Item
100VA
Input
AC400V
±
±±
±
10% 1
∅
∅
∅
∅
Power Supply
Output
AC240V
±
±±
±
10% 1
∅
∅
∅
∅
Ambient Temperature
0°C To 55°C
S=KVA
P=KW
Pf
×
××
×
n = 0.75 (Correction Factors)
S=
KW
Pf
×
××
×
n(0.75)
P=
2.35Kw
0.75
=3.133KVA………………….. (1)
P=
6.58Kw
0.75
=8.773KVA………………….. (2)
Power Equipment Capacity=
3.8.773KVA
2
=5.935KVA
Содержание TPR1100
Страница 1: ...D E C 0 0 2 0 4 TAILIFT LTD 2006 RADIAL DRILLS TPR720A TPR820A TPR920A TPR1100 Operation Manual...
Страница 6: ...1 5 b 2 The rear view only for TPR 1100 C Oil filler position and Oil Drain outlet position Gearbox...
Страница 7: ...1 6 Arm elevating motor For TPR 720A TPR 820A TPR 920A Arm elevating motor For TPR 1100...
Страница 30: ...5 4 5 1 2 For TPR 1100 The front view of TPR 1100...
Страница 40: ...5 14 Examples of clamping using the universal clamp...
Страница 81: ...9 6 9 6 Electrical Circuit Diagram For TPR720A TPR820A TPR920A Standard...
Страница 84: ...9 9 9 8 Electrical Circuit Diagram For TPR1100 Standard...