background image

english 

  

                                                                                                                    

Taifun®  LTB 

  User  Manual

 

 

 

 

 

 

 

 

 

 

18

 

Further functions of the Taifun® LTB 

Turn on/off keylock  

Press the button 5 times  

Now you can remove the atomizer (for example to refill, for 
cleaning or to change the coil). 
 
 
 
 
 

 

Adjusting the voltage 

With the power switch on the back, the voltage can be 
adjusted (7 positions). 

The lowest setting (left) is 3.4 volts, the maximum setting 
(right) is 4.6 volts. 

The maximum current is 5 amps. 

 

Liquid detection  

It is required to give two drops of the salt solution into the 
connection chamber.  
Now the sensor (see picture) can detect the liquid. 
 

 

 

 

Antitheft  

(optional function) 

 

An alarm sounds, if the atomizer is removed.  

To stop the alarm you have to screw the atomizer back on. 

 

Содержание SmokerStore Liquid Test Bar

Страница 1: ...Taifun GT II GT II Air Bedienungsanleitung deutsch User Manual english LTB...

Страница 2: ...ese are 10 Taifun GTII atomizers specially modified for the LTB similar to the atomizers that you already know By pushing on one of the 10 control buttons the respective atomizer is activated and vapo...

Страница 3: ...Taifun LTB during power on in delivery status 14 Status display and error display of the Taifun LTB during use 15 Further functions of the Taifun LTB 18 Turn on off keylock 18 Antitheft 18 Turn funct...

Страница 4: ...r example youth protection has to be considered by the shop owner x The manufacturer cannot be held liable for any direct or indirect health damage resulting in use of the device or the use of liquids...

Страница 5: ...been tested at the factory according to VDE 0701 0702 electrical safety testing x This test must be repeated each year to ensure user safety x The device is designed for a maximum working time of 12 h...

Страница 6: ...the device or the power cord shows visible damage x the device contains loose parts noise from loose parts for example during transport x the device no longer works as intended x if the device has bee...

Страница 7: ...g atomizers Fire and burn hazard x Do not use in areas which could be enriched with flammable gases vapors or dusts Risk of explosion x Never expose the device to rain moisture or humidity x Do not ex...

Страница 8: ...onment temperature range 5 to 30 C non condensing x Storage temperature range 0 to 50 C x Output of about 19 watts x Adjustable voltage of 3 4 volts left to 4 6 Volts right clockwise applies to all 10...

Страница 9: ...operation Kanthal or NiCr wire 1 00 0 1 U 4 4 Volt x Lack of liquid detection activated Dicodes temperature wire NiFe30 0 5 0 6 at room temperature U 4 0 Volt RECOMMENDATION OF THE MANUFACTURER We re...

Страница 10: ...warranty case Only the failure of two or more LEDs is a valid warranty If you have any difficulties problems or questions please contact your dealer or the manufacturer The user manuals for the Taifun...

Страница 11: ...the correct function of the sensor After a while a salt crust will form inside the chamber As long as the salt crust remains visible adding of further salt solution is not necessary Coil building see...

Страница 12: ...e Then the Taifun LTB performs a self check LED Check 1 All 10 LED lights will briefly turn red LED Check 2 All 10 LED lights will briefly turn green Status display of functions The LED Pos 1 6 from l...

Страница 13: ...ugh the selected atomizer without generating steam Generating steam Now steam is generated for a period of a maximum of 6 seconds The steam comes out on the upper side of the atomizer and can then be...

Страница 14: ...an leaking atomizer standard green activated 2 Lack of liquid detection detects a dry wick standard red deactivated normal wire mode is active 3 Antitheft Alarm optional function standard red deactiva...

Страница 15: ...ess button 5 times Status Description Single LED is GREEN Ready to use Valid atomizer detected Troubleshooting Status Description All LEDs are GREEN changing Stand By Mode After a few minutes the Taif...

Страница 16: ...in Status Description Single LED flashes RED once per second Lack of liquid during vaping detected Only works with thermal wire NiFe30 Troubleshooting Refill the tank with liquid Then a reset is requi...

Страница 17: ...ed atomizer or the anti theft protection alarm you can deactivate these functions of the Taifun LTB temporarily and continue operating with the remaining atomizers until completing troubleshooting ste...

Страница 18: ...switch on the back the voltage can be adjusted 7 positions The lowest setting left is 3 4 volts the maximum setting right is 4 6 volts The maximum current is 5 amps Liquid detection It is required to...

Страница 19: ...while holding the the corresponding key 1 6 IMPORTANT Between turn off and on again there should be a minimum of 5 sec waiting time to clear the memory During switching it is necessary to hold the cor...

Страница 20: ...ss the button 6 and keep it pressed Step 3 With the other hand you turn the device back on Step 4 It starts with the initial LED check 1 and LED check 2 Then the LEDs pos 1 6 from left to right light...

Страница 21: ...essed Step 3 With the other hand you turn the device back on Step 4 It starts with the initial LED check 1 and LED check 2 Then the LEDs pos 1 6 from left to right light up briefly and indicate the cu...

Страница 22: ...led off upwards Step 3 Now the sealing ring can be removed Step 4 Unscrew the atomizer Step 5 Now you should check if liquid is in the connection chamber Step 6 If necessary remove the liquid using a...

Страница 23: ...th Do not use abrasive sponges scouring agents acid solution or fatty cleaners or sharp objects for cleaning For stubborn dirt a lightly moistened cloth may be used with warm water and a mild househol...

Страница 24: ...ers must not remain on the Taifun LTB during transport If you don t remove the atomizers it is possible that liquid will enter the air pipe Visual controll of the chambers Once the atomizers are remov...

Страница 25: ...cing the fuse of the Taifun LTB Disconnect the Taifun LTB from the power source and pull the fuse on the rear out Now the fuse can be replaced Insert the new fuse Then the Taifun LTB can be connected...

Страница 26: ...Omega Pic 8 Attach the chamber sleeve from the top Pic 9 Now push the chamber sleeve down until it clicks into place Pic 10 Guide the cotton through the coil Pic 11 Pull the chamber sleeve up until it...

Страница 27: ...till holding the atomizer upside down IMPORTANT Do not overfill The capacity of each tank is about 5 ml Visual controll of the chambers Before you screw the atomizer back on the device you should insp...

Страница 28: ...english Taifun LTB User Manual 28 SMOKERSTORE ELECTRONIC VAPING PRODUCTS SmokerStore GmbH www smokerstore de...

Отзывы: