25
2.6.15 Floor Input Sen. Setting
a).
Use the “ / ”
button to adjust the floor input
sensitivity (press and hold the " / " button will
adjust numeric value quickly), range from –6 dBV -
+18 dBV;
b).
Press the "MENU" button to save and return to the
upper level menu.
2.6.16 IR Audio In Gain Setting
a).
Use the “ / ”
button to adjust the IR signal
audio
in gain (press and hold the " / " button will adjust
the numeric value quickly), range from –6 dB - +6
dB;
b).
Press the "MENU" button to save and return to the
upper level menu.
2.6.17 SI Channel Parameters Setting
Monitor the language channels and set up their states.
Press the “MENU” button to view the channel state. If a
channel has not been fed with language output
temporarily, the LCD displays as in the following figure:
If the microphone of the Interpreter unit in the booth is
active, the audio parameters of the Interpreter unit will
be displayed as in the following figure and can be
adjusted:
Under channel state interface, press “MENU” to select
the channel number or parameter and press “ / ” to
change the channel number or parameter.
2.6.18 Floor Distribution Setting
Select distribution of floor audio to used simultaneous
interpretation channels or not.
a).
Use the “ / ”
button to select “Yes” or “No”;
b).
Press the "MENU" button to save and return to the
upper level menu.
2.6.19 Floor DRC Limit Setting
Setup the DRC limit of the floor channel in the system.
a).
Press the " / " button to select the DRC limit of
the floor channel between: OFF, -3 dB FS, -6 dB
FS, -9 dB FS, -12 dB FS and -15 dB FS;
b).
Press the "MENU" button to save and return to the
upper level menu.
2.6.20 Sampling Rate Setting
Select the sample rate between 32 KHz and 48 KHz. If
“48 KHz" sampling frequency is selected, the system
response frequency is 30 Hz - 20 KHz; if "32 KHz"
sampling frequency is selected, the system response
frequency is 30 Hz - 16 KHz.
a).
Press the " / " button to select "32 KHz" or "48
KHz";
b).
Press the "MENU" button to save and return to the
upper level menu.