19
If it is ok, then switch off the mic and switch on the next
mic.
If it is not ok then keep the mic switched on and got to
“Set Active” setting in the CMU and increase or
decrease the mic gain.
Continue with the next mic.
“Set Active”
a). Press the “
Õ
/
Ö
” button to adjust the gain of all
microphones (press and hold the “
Õ
/
Ö
” button will
adjust
numeric
value
quickly),
range:
-15 dB - 15 dB;
b). Press the “MENU” button to save and return to
upper level menu.
10. “Microphone Lowcut Setting”
Select activating high-pass filter (low-cut switch) to cut
low frequency elements from the microphone audio or
not.
a). Press the “
Õ
/
Ö
” button to select “Set All Mics” or
“Set Active”;
b). Press the “MENU” button to go to the next step;
c). Press the “
Õ
/
Ö
” button to select “Yes” or “No”;
d). Press the “MENU” button to save and return to the
upper level menu.
11. “Microphone Power Setting”
There are two menu items for phantom power setting of
handheld microphone interface on Multi-function
Connector HCS-4340A/50P. This submenu is
inaccessible if no phantom unit is connected.
“Set All Mics”
“Single”
a). Press the “
Õ
/
Ö
” button to select “Set All Mics” or
“Single”;
b). Press the “MENU” button to go to the next step:
“Set All Mics”
a).
Press the “
Õ
/
Ö
” button to select phantom power
on/off for condenser microphone;
b).
Press the “MENU” button to save and return to the
upper level menu.
“Single”
a). Press the “
Õ
/
Ö
” button to traverse all connected
HCS-4340A/50P;
b). Press the “MENU” button to select phantom power
on/off;
c). Press the “EXIT” button to exit after setting.
12. “Headphone Monitor Setting”
The audio output can be monitored with a headphone
at the monitor jack on the front panel of the CMU.
“Headphone monitor setting” includes two submenus:
“Monitor Channel Select”
“Volume”
a). Press the “
Õ
/
Ö
” button to select “Monitor Channel
Select” or “Volume”;
b). Press the “MENU” button to go to next step;
“Monitor Channel Select”
Monitor Channel Select includes: line output 1-2.