background image

TECHNICAL SPECIFICATIONS

Operating Pressure:

Suitable for mains pressure.

Min. 150kPa, Max. 500kPa

Operating Temperature:

Recommended maximum

49°C. Max. 60°C

Inlet Connections:

All 1/2"
All pipework must be

thoroughly flushed prior to

installation of the system.

TAHI SHOWER SYSTEM

INSTALLATION GUIDE

Содержание METHVEN

Страница 1: ... Suitable for mains pressure Min 150kPa Max 500kPa Operating Temperature Recommended maximum 49 C Max 60 C Inlet Connections All 1 2 All pipework must be thoroughly flushed prior to installation of the system TAHI SHOWER SYSTEM INSTALLATION GUIDE ...

Страница 2: ...dpiece Hose elbow Hose Shelf trays Shelf Rail bottom 45 cover Rail bottom bracket cover Attached footrest cover Rail top bracket Rail Rail bottom bracket Separate footrest spacer Footrest assembly Handpiece holder A B C Only included when you purchase footrest option Drencher outlet adaptor Attached drencher cover Discard if installing stand alone drench shower Drench Shower exploded diagram ...

Страница 3: ...Shower Fastening Zone load bearing support required Fastening Zone load bearing support required 380mm 360mm Hole Ø25mm 2100mm Recommended outlet height 2070mm 240mm Floor Elbow height at installer s discretion Recommended 2010mm X X 13mm 16mm 3mm Pre wall lining requirements Install properly anchored female 1 2 wingback at least 25mm from the front of the unlined wall Screw in test nipple When th...

Страница 4: ...er drencher bracket Seal holes and drive in screws and wall plugs if appropriate Ensure edge of bracket is plumb then mark bottom screw hole Tighten using a lever until bracket is pulled flat against wall Ensure edge is plumb mark plumb line to floor and mark screw holes Tighten using a lever until bracket is pulled flat against wall Swing aside Drill clearance into lining then pre drill support R...

Страница 5: ...b line Mark holes Set aside drill clearance into lining and pre drill support Slide shelf if included and handpiece holder on to top of rail Push rail and bracket back on to top bracket and clip on angled cover Seal holes Drive in screws and wall plugs where appropriate Check alignment with plumb line Mark holes No footrest Separate footrest Go to 19 on page 8 Clip on cover 1 2 575mm ...

Страница 6: ...nd insert trays Environmental Statement Removing flow restrictor under filter cap or in hand shower will increase water consumption Clean filter baskets periodically Do not use any sharp objects to clean nozzles Water contains lime which remains on the surface after the water has evaporated These lime deposits can be prevented from forming by wiping immediately after use To clean the chrome plated ...

Страница 7: ...that it is suitable for use under the operating conditions specified in this instruction sheet For your warranty please refer to www methven com or call Customer Service New Zealand 0800 804 222 Australia 1300 638 483 USA 800 975 5409 UK 0800 195 1602 290240 Issue A ...