1. Magnification level

 

Use a keyboard or the control box to choose magnification  

 

level. You should only see the sample, not the sample 

 

drawer or sides of the light eliminator. 

 

2. Live View 

 

Use this button to toggle between live and snapshot,

 

In Live mode, the live camera image is active. In Still Image 

 

mode, the latest snapshot will be shown.

 

3. Snapshot

 

Use this button to take a snapshot of the live image.

 

The snapshot will not be saved automatically. The    

 

snapshot is used for toggling between “Live and Still Image  

 mode”.

 

4. White balance calibration (WBC) 

 

Perform an automatic white balance adjustment in order to 

 

get colors displayed correctly on screen.

 

NB! It is recommend to leave the microscope turned on for  

 

30 minutes before performing the WBC.

 

Place the White balance calibration card in the allocated  

 

slot on the Calibration card fixture and place them both on  

 

top of the Sample drawer as shown below.  

 

Then, insert the sample drawer with calibration card fixture  

 

and calibration card into the sample drawer positioner and  

 

press the white balance calibration button on the monitor  

 

to start the calibration. 

 

A white balance calibration is made each time the camera  

 

is turned on to adjust to the given light conditions. A white  

 

balance calibration must also be made every time the light  

 

conditions change.

 

NB! If the Sample drawer with calibration card and   

 

White balance calibration card fixture is not inserted  

 

into the camera field of view when the unit is turned

 

on, the white balance will be incorrect and it will be

 

necessary to perform the white balance adjustment

 

process as described previously.

 

NB! Once the WBC has been performed, place the White  

 

balance calibration card into its UV protection sleeve.  

 

Storing it in the sleeve will prolong the life expectancy of  

 

the White balance calibration card.

 

5. Save Image 

 

This button provides the possibility to save the current view  

 

with graphics. When activated, the information panel  

 

will also appear from the saved image (see pt. 15). 

 

 

When saving an image, an information window will appear  

 

for a few seconds showing the file name and storage  

 location. 

 

The image will be saved on the inserted USB memory stick.  

 

If a USB memory stick is not attached, the image is saved  

 

internally on the microscope, provided the share file mode  

 

is turned on in General settings.

2.  TOOLBAR