Tadiran Domestic Pool Type Technical Manual TCAC-RTSM-20150203
33
Press
ON/OFF
button after all the above have finished and the system will run as the setting.
And simply press the same button to stop it.
5) Operation status display
2.13 Spot check
Main control board spot check
Sequence
System operation parameters
Remarks
1st
Normal display
Value of T6
2nd
Mode code
0: 6KW; 1: 8KW; 2: 12KW; 3: 14KW
3rd
Operate mode
1 Cooling; 16 Water heating
;
4 Pump; 8
standby
4th
Fan speed
0: OFF 1: Low 2:High
5th
Ambient temperature
Value of T4
6th
Compressor discharge temperature
Value of Tp
7th
Pipe temperature
Value of T3
8th
Inlet water temperature
Value of T6
9th
Outlet water temperature
Value of Tout
10th
Compressor current
Value of current
11st
Setting water temperature
Value of Ts
12nd
The last error code or protection code
Display the latest error code or protection code
2.14 Accessories
Name
Qty.
Sharp
Purpose
Installation & Owner’s Manual
1
Installation and use instruction.
Seal ring
1
Discharge condensate water
Water outlet joining pipe
1
Discharge condensate water