2.
Location & Installation:
Planning
:
Included in Package:
SR506-5 switching relay; six zone
2 Spare fuses attached to inner cover
Instruction sheet
Strap-on temperature sensor
Tools & Material Needed
:
Small straight blade screwdriver
Phillips screwdriver
Torpedo level
Wire strippers
Screws or hardware for mounting
Electrical connectors for field wiring
Low and live voltage wiring (per code)
Location
: Do not mount to a surface that exceeds 104°F (40°C). The unit must be only located in dry
interior locations. Use only copper conductor supply wire suitable for at least 105° C. All circuits
must have a common disconnect and be connected to the same pole of the disconnect. Product is
not suitable for installation in hazardous locations.
Installation
:
1.
Hang the panel on a wall with one mounting screw.
2.
Level the panel.
3.
Install other 3 mounting screws