REPLACEMENT PARTS

Part#

Description

198-213 RP

Casing O-ring

198-214 RP

Wiring plug connector (green)

198-215 RP

Terminal box cover (black)

198-217 RP

Terminal box cover screws (5 per bag)

0010-025 RP

Integral Flow Check (IFC®)

007-007 RP

Flange Gasket Kit

UNION FITTING SETS 

(SOLD SEPARATELY)

Part#

Description

UFS-050S

1/2” Sweat tailpiece set

UFS-050T

1/2” NPT tailpiece set

UFS-050P

1/2” Press tailpiece set

UFS-075S

3/4” Sweat tailpiece set

UFS-075T

3/4” NPT tailpiece set

UFS-075P

3/4” Press tailpiece set

Lead-Free Shut-Off                           FLANGE 

(SOLD SEPARATELY)

Part#

Description

SFL-050T

1/2” NPT

SFL-050S

1/2” Sweat

SFL-075T

3/4” NPT

SFL-075S

3/4” Sweat

SFL-100T

1” NPT

SFL-100S

1” Sweat

SFL-125T

1-1/4” NPT

SFL-125S

1-1/4” Sweat

SFL-150T

1-1/2” NPT

SFL-150S

1-1/2” Sweat

-9-

Taco

Grundfos

Armstrong

Xylem/B & G

Wilo

005
006
007
008
0015
007e

UP15-10
UP15-42
UPS15-55
UPS15-58
Alpha 15-55
Alpha2 15-55

Astro 225
Astro 230
Astro 250
Astro 20
Astro 25
Astro 30
Astro 30-3
Astro 50-3
Compass H20-20

ecocirc 19-16
NBF-22/NRF-22
NBF-25/NRF-25
NBF-9/NRF-9F/LW
SSF-9U/LW

Star S 16
Star S 21
Stratos ECO 16

0015e3 Pump Replacement Cross Reference

Содержание 0015e3

Страница 1: ...tions Use on open loop potable hot water recirculation systems with up to 1000 feet of pipe or closed loop hydronic heating systems Not suitable for chilled water systems Taco circulator pumps are for indoor use only employer uniquement a l interieur Acceptable for use with water or maximum of 50 water glycol solution FEATURES Three easy settings to match system requirements LOW MEDIUM HIGH Replac...

Страница 2: ...ricant pour connaître la compatibilité de liquides CAUTION Installations at elevations over 5000 feet must have higher fill pressure of 20 psi minimum to prevent pump cavitation and flashing Premature failure may result Adjust expansion tank pressure to equal fill pressure A larger size expansion tank may be required ATTENTION Des installations à des altitudes de plus de 1600 mètres doivent présen...

Страница 3: ...n system Open all isolation valves Once system is filled close the fixture at the highest point in the system Close isolation valve on pump discharge Option No 1 location Open drain valve on pump discharge until all remaining air has been purged Close drain valve Operate pump until all remaining air is purged from bearing chamber 2 3 4 5 6 7 ...

Страница 4: ...Open FF valve Open V2 PV4 to purge last zone First Zone 3 Close FF Valve Close V2 PV4 Repeat steps 1 to 6 for each additional zone purge zone 1 last Open V1 when all zones are purged Adjust system to desired operating fill pressure if required 2 3 4 5 6 7 8 9 V1 V2 V3 Shut off Isolation Valve P Taco circulator with IFC installed FF Fast Fill Boiler Feed Valve PV4 Purge Valve ...

Страница 5: ...ing the circulator See page 3 for recommended air purging steps CAUTION To reduce the possibility of noise transmission be sure to add vibration dampeners to piping when mounting circulator to wall or floor joists ATTENTION Pour réduire la possibilité de transmission de bruit veillez à ajouter des amortisseurs de vibration à la tuyauterie lors du montage du circulateur sur des chevêtres de mur ou ...

Страница 6: ...to access Green Mode CAUTION Never run the circulator dry or permanent damage may result ATTENTION Ne laissez jamais le circulateur tourner à sec des dommages permanents peuvent en résulter WARNING Use supply wires suitable for 90 C AVERTISSEMENT Employer des fils d alimentation adeqauts pour 90 C WARNING Disconnect power when servicing AVERTISSEMENT Couper l alimentation lors de l entretien CAUTI...

Страница 7: ...ressure variable speed HIGH 18 feet of head max full fixed speed CAUTION Do not attempt to remove LED panel from circulator Serious damage to circulator electronics may result ATTENTION N essayez pas de retirer le panneau de LED du circulateur Des dommages sérieux à l électronique du circulateur peuvent en résulter Selection options are LOW MEDIUM or HIGH On HIGH setting the 0015e3 runs at full sp...

Страница 8: ...or impeller rotation 7 If the circulator still doesn t run it will need to be replaced FAULTS CONTROL PANEL CAUSES REMEDIES The circulator is noisy LED on Suction pressure is insufficient cavitation Increase the system suction pressure within the permissible range LED on Presence of foreign bodies in the impeller Disassemble the motor and clean the impeller Loud noises of water circulation Flashin...

Страница 9: ...ilpiece set UFS 075P 3 4 Press tailpiece set Lead FreeShut Off FLANGE SOLDSEPARATELY Part Description SFL 050T 1 2 NPT SFL 050S 1 2 Sweat SFL 075T 3 4 NPT SFL 075S 3 4 Sweat SFL 100T 1 NPT SFL 100S 1 Sweat SFL 125T 1 1 4 NPT SFL 125S 1 1 4 Sweat SFL 150T 1 1 2 NPT SFL 150S 1 1 2 Sweat 9 Taco Grundfos Armstrong Xylem B G Wilo 005 006 007 008 0015 007e UP15 10 UP15 42 UPS15 55 UPS15 58 Alpha 15 55 A...

Страница 10: ... 10 NOTES ...

Страница 11: ... 11 NOTES ...

Страница 12: ...consequential damages so these limitations or exclusions may not apply to you LIMITED WARRANTY STATEMENT Taco Inc will repair or replace without charge at the company s option any Taco product which is proven defective under normal use within three 3 years from the date code In order to obtain service under this warranty it is the responsibility of the purchaser to promptly notify the local Taco s...

Отзывы: