Description of functions
Pump control functions
Timer control
●
Interval mode
ON/OFF operations are repeated by setting the ON
period and OFF period.
Number of programs that can be set: 1 pattern each for
ON period and OFF period
Periods that can be set: 1 to 9999 minutes
✽
Whether or not to use pulse input-based proportional
control can be selected.
When use of this control is selected, the pump operates
at the pulse frequency-division or frequency-magnifica-
tion that is set during the ON period of the interval.
Setting examples: ON period = 5 minutes
OFF period = 3 minutes
5 min.
3 min.
5 min.
3 min.
5 min.
5 min.
3 min.
ON
OFF
START
●
DAY mode
The pump operates automatically every day at the ON
time and OFF time that have been set for the same
periods.
Number of programs that can be set: 9 patterns
Times that can be set: ON time = 0.00 to 23:59
OFF time = (after ON time) up to 24:00
✽
The same time cannot be set for the ON time and
OFF time.
✽
Whether to use interval operation and pulse input-
based proportional control can be selected.
✽
The DAY mode cannot be used together with the
WEEK mode.
Setting example
Program No.
1
2
3
4
ON time
1:00
6:30
11:30
17:15
OFF time
5:00
10:30
15:15
21:15
0:00
5:00
10:30
15:15
21:15
24:00
1:00
6:30
11:30
17:15
ON
OFF
●
WEEK mode
The pump operates automatically every week at the ON
time and OFF time that have been set for the same day
of the week and for the same periods.
Number of programs that can be set: 7 patterns (1 pat-
tern every day)
Times that can be set: ON time = 0.00 to 23:59
OFF time = (after ON time) up to 48:00
✽
The same time cannot be set for the ON time and OFF time.
✽
Whether to use interval operation and pulse input-
based proportional control can be selected.
✽
The WEEK mode cannot be used together with the DAY mode.
Program setting example
Program
No. (day)
1
(Mon.)
2
(Tue.)
3
(Wed.)
4
(Thu.)
5
(Fri.)
6
(Sat.)
7
(Sun.)
ON time
9:00
9:00 15:00
9:00
9:00
0:00 No settings.
OFF time 18:00 18:00 30:00 18:00 18:00 42:00 No settings.
Pump operation
1 (Mon.)
2 (Tue.)
3 (Wed.)
4 (Thu.)
5 (Fri.)
6 (Sat.)
7 (Sun.)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0:00
18:00
24:00
9:00
0:00
18:00
24:00
9:00
0:00
18:00
6:00
24:00
9:00
0:00
18:00
24:00
9:00
0:00
24:00
15:00
0:00
24:00
0:00
24:00
18:00
NOTE
• DAY mode or WEEK mode + interval operation
The pump repeats the interval operation within the ON period in each mode. The values set in each program
serve as the number of strokes.
• DAY mode or WEEK mode + pulse input-based proportional control
The pump operates at the pulse frequency-division or frequency-magnification that was set within the ON
period in each mode.
• DAY mode or WEEK mode + interval ope pulse input-based proportional control
The pump operates at the pulse frequency division or frequency-magnification set when the interval operation is
ON within the ON period in each mode.
• External operation and stop input signal control
The timer modes can be used together with external operation and stop input signal control.
08-32̲EM-127̲PW(E).indd 30