25
Operation
Air releasing
Air-release method C
(1) Turn off the pump’s power, and release the pressure
inside the discharge-side pipe.
(2) Set the stroke-length adjustment dial to the 100%
marking on the scale.
Stroke length
adjustment dial
(3) Turn on the pump’s power.
(4) Set the discharge capacity to the maximum. (This
can also be done by pressing the [
] and [
] keys
simultaneously during operation.)
(5) Press the [STOP/START] key to start operating the
pump.
(6) Press the [STOP/START] key to shut down the
pump.
Air-release method D
(1)
Turn off the pump’s power, and release the pressure
inside the discharge-side pipe.
(2) Loosen slightly the air-release nozzle at the bottom
right of the pump head by turning it counterclock-
wise.
(3) Insert the hose pump provided, operate the pump,
and draw up the chemical until all the air in the
pump head comes out.
Hose pump
Air-release nozzle
(4) Close the air-release nozzle by turning it clockwise.
IMPORTANT
•
If the air-release nozzle is loosened too much,
it will fall off, damaging the packing.
Take care not to loosen the nozzle too much.
Air-release method E
(1) Turn off the pump’s power, and release the pressure
inside the discharge-side pipe.
(2) Disconnect the discharge side hose.
(3) Insert the accessory hose pump into the joint.
(4) Deflate the hose pump several times.
The air remaining inside the suction side hose and
pump head is discharged, and the chemical liquid
fills the inside of the pump head.
(5) Return the pipe to its original state when chemical
liquid emerges from the hose pump.
08-32̲EM-127̲PW(E).indd 25
2014/11/17 11:43:57
Содержание PW Series
Страница 67: ......
Страница 68: ...EM 127 8 03 2014 11 DDD...