4.
Make sure all dipswitch is X0XX, then turn ON batteries.
5.
After all batteries running and buzzer of master battery in group1 rings 3 times.
Means all groups are online.
6.
Change the dip switch of
master battery in group 1
to X1XX. Then connect commu
-
nication cable between LV-HUB and master battery in group 1.
7.
Then turn ON LV-HUB.
Detailed information please refer to manual of LV-HUB.
Each battery pile can configure maximum 16pcs R4824/R4836
6. Trouble shooting
•
Communication related problem
Unable to communicate with inverter on compatible list.
Possible conditions:
1.
RS485: baud rate. Check the dip switch1, set to correct one, and restart. All master
battery shall be the same.
2.
CAN: terminal resistance. Check the dip switch2, set to 0 and retry.
3.
CAN: pin. Try connect the CAN-H,L,GND only and do not connect other pins to in
-
verter.
•
Functional related problem
1.
Whether the battery can be turned on or not
2.
If battery is turned on, check the red light is off, flashing or lighting
3.
If the red light is off, check whether the battery can be charged/discharged or not.
27
R4824_Operating_Manual_17.05.2021.indd 27
R4824_Operating_Manual_17.05.2021.indd 27
17.5.2021 14:16:01